We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.
Working hours: Mon - Sun. 8am - 8pm
Proudly serving the entire UK!
Company
99.99% PATHOGEN KILL
Inline UV for the drinking-water tap
Point-of-use sterilisation
Inline post-RO · Sterile water at the dedicated kitchen tap
99.99% kill rate
E.coli · Legionella · Viruses · Cryptosporidium cysts
Pairs with any RO system
Standard PRO · P’URE Balance · Direct Flow · 1/4″ JG inline
Tiny footprint
Fits under-sink alongside the RO · No plant-room space needed
No chemicals, no taste change
Light kills · Nothing added · Minerals untouched
9,000 hr lamp life
Annual lamp swap · Nothing else to service
Works in seconds
Water sterilised as it passes through the reactor · No batch storage
Right answer for clinics & pregnancy
Where ‘99.8% is probably fine’ isn’t a good enough answer
The HR-60 fits inline between the RO storage tank and the dedicated drinking-water tap. RO water is already very clean — the membrane has removed 99.8% of contaminants — and importantly is free of sediment. No pre-filter needed; the UV chamber stays clean indefinitely.
Pre-filtered water enters the AISI 304 stainless steel reactor — a long, narrow tube engineered to force water past the lamp at a controlled flow rate. No bypass paths, no dead zones, no untreated water.
A low-pressure mercury lamp emits at 254 nanometres — the wavelength most damaging to microbial DNA. The lamp sits inside a quartz sleeve that keeps it dry while transmitting the UV light into the water.
UV-C photons damage the genetic material inside any micro-organism passing through — bacteria, viruses, protozoan cysts. Damaged DNA can’t replicate. The pathogen is functionally dead. This happens in milliseconds.
The reactor is sized so every drop of water at design flow receives at least a 30 mJ/cm² UV dose — the threshold for 99.99% kill on E.coli, Legionella, hepatitis A, and Cryptosporidium cysts. Tested to NSF Class B equivalent.
No batch storage, no waiting. The system runs 24/7 — pathogens never get a chance to multiply downstream of the chamber. Every tap in the house receives sterilised water on demand at full mains flow.
Always-on operation
UV is continuous — lamp on 24/7. ~30 W standby draw, about £65/year electricity. Switching the lamp off and on shortens its life and risks contamination, so the system is designed to run permanently.
Power LED
Green LED on the ballast box confirms the lamp is energised. Mounted at eye level in the plant room or cupboard — visible without opening anything. The one indicator you check during the year.
Lamp-failure alarm
Audible buzzer plus red LED if the lamp fails or the ballast loses contact. We're notified automatically via the service plan; you ring us, we replace the lamp. The alarm doesn't stop water flow — it just tells you treatment isn't happening.
Inlet isolator
Full-bore ball valve upstream of the reactor. Engineer’s on/off for service. Use it together with the outlet isolator to drop the reactor without losing supply to the house.
Outlet isolator
Matching ball valve downstream. With both isolators closed and the bypass opened, the rest of the house still has water during a lamp swap.
Bypass valve
Pipe loop around the reactor, with a manual valve. Engineer opens it to keep water running to the property during service. Closed in normal use — everything routes through the reactor.
Drain valve
Small drain on the reactor low point. Used to flush the chamber after a lamp swap, before bringing the system back online.
Pre-filter housing
Clear-bowl housing on the inlet side, with a manual relief button on top. Press to drop the bowl pressure before opening for a cartridge change. The only part you might touch yourself between visits.
Stainless reactor chamber
AISI 304 stainless steel tube with electropolished interior. Engineered flow path forces every drop past the lamp. Compact format — fits under-sink alongside an RO housing block.
UV-C lamp
Low-pressure mercury lamp emitting at 254 nm. 9,000-hour rated life. Replaced annually as part of the service plan. Only consumable in the system.
Quartz sleeve
Clear quartz tube around the lamp keeps it dry while letting UV-C pass through into the water. Inspected and wiped annually with the lamp change.
Electronic ballast
Small wall-mounted ballast box delivers regulated power to the lamp. Power LED on the front, plus lamp-failure alarm. CE-marked.
1/4" JG fittings
Push-fit John Guest 1/4-inch fittings on inlet and outlet. Plugs straight into the food-grade tubing of any Ecosoft RO. Tool-free service.
Mounting bracket
Small stainless bracket fixes the reactor to the side of the kitchen cabinet. Horizontal or vertical orientation. Stays out of the way.
Plug-in transformer
230 V mains via standard 13 A socket. ~15 W standby draw — lamp runs continuously. Annual electricity cost around £35.
No pre-filter needed
Unlike a whole-house UV that needs a sediment pre-filter to keep the chamber clear, the HR-60 sits downstream of an RO that’s already removed every particle. The chamber stays clean.
Invisible operation
Whole-house UV sits on the rising main, usually in a plant room, garage or under-stairs cupboard. You don’t see it, you don’t touch it. Water just becomes pathogen-free at every tap.
No taste change
UV kills with light, not chemistry. Nothing added, nothing removed except the pathogens. Minerals untouched, chlorine (if your supply has any) untouched, taste exactly the same as before.
Every tap, all day
Drinking, cooking, brushing teeth, washing salad, filling the bath. All your water is the safe water — not just one dedicated kitchen tap. Matters most for well-fed and cistern-fed properties.
Power-on continuously
Lamp runs 24/7. ~30 W standby, around £65/year in electricity. Cycling the lamp on/off shortens its life dramatically — the system is designed to run permanently.
Annual lamp swap
Lamp rated 9,000 hours — about 12 months continuous. Replaced on the annual service visit. Quartz sleeve inspected and wiped at the same time. The kit is around £65 plus the visit.
Pre-filter swap
Sediment cartridge replaced every 6–12 months depending on water quality. Quick visual check — if the cartridge has turned brown, it’s done its job. DIY in 5 minutes or part of the annual visit.
Quartz sleeve clean
Every 12 months the quartz sleeve gets wiped to remove any film that could shadow the UV. Done as part of the lamp swap. Replaced outright if scale or biofilm has fixed to the surface.
2-yr warranty
Full 2-year manufacturer warranty on the reactor and ballast. Stainless chamber rated 10-year design life. CleverBloom handles any claim direct with Ecosoft.
Heat pump unit only. Radiators, UFH, and emitters are on the heating page.
UV HR-60
Inline post-RO UV-C sterilisation · 0.22 m³/hr · drinking-water polish
OPTIONAL ADD-ONS
UV HR-60
Inline post-RO UV-C sterilisation · 0.22 m³/hr · drinking-water polish
UV HR-60
Inline post-RO UV-C sterilisation · 0.22 m³/hr · drinking-water polish
OPTIONAL ADD-ONS
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur.
Block quote
Ordered list
Unordered list
Bold text
Emphasis
Superscript
Subscript

_11zon%20(1).webp)
Call us at 07526 985258
or leave your contact information below,
and we'll get back to you soon.
Join our certified installer network — leads, products, and technical support provided.
We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.
Working hours: Mon - Sun. 8am - 8pm
Proudly serving the entire UK!
© 2026 Clever Bloom — All rights reserved
Company registered in England and Wales / Company number: 14242566.