Clever Bloom - Smart Home and MVHR Ventilation Installation UKClever Bloom - Smart Home and MVHR Ventilation Installation UK
  • Solutions
    • Air
    • Heating
    • Water Treatment System
    • EV charger
    • Smart home
  • Join us
  • Ventilation Applications

Solutions

  • Air
  • Heating
  • Ev Charger
  • Smart Home
  • Water Treatment Systems

Information

  • Ventilation Applications
  • Join Us

Working hours: Mon - Sun. 8am - 8pm

Proudly serving the entire UK!

Free consultation on WhatsApp
07526 985258
  • Home
  • /
  • Air
  • /
  • inVENTer X-Flow Plus
Cross-flow heat exchanger
Built-in CO₂ + temp + humidity sensors
Dn,e,w sound insulation up to 55 dB
Flair XL inner cover
Flex Office weather hood — RAL choice

inVENTer X-Flow Plus

Large open-plan rooms · Commercial · 300 m³/h capacity

300m³/h
max airflow
87%
heat recovery
12–32dB
at 2 m distance
+60%
capacity vs standard
3 sensors
CO₂, temp, humidity
5 yr
warranty
get a quote
Whats App instead
Why switch

87% of room heat stays in your room

Cross-flow exchanger · continuous bidirectional

300 m³/h continuous airflow

60% more capacity than X-Flow standard

Senses what the room actually needs

Built-in CO₂, temperature, humidity

ePM 10-70% premium filtration

Captures fine particulates · the highest in the inVENTer range

No external controller, no wiring drama

Touchpad on the device · plugs into 230V outlet

Energy class A · Ecodesign rated

Specific power 0.15 W/(m³/h) · standby <1 W

German engineering, since 1999

DIN 1946-6 · KfW proven · ISO 9001

Flaps close automatically when off

Auto-shutter · no draughts during pause

How it works
Specification
Control/App
Installation
components
Aftercare

Continuous bidirectional flow

The X-Flow runs supply and exhaust simultaneously through separate ducts. One air stream pulls stale air out; another supplies fresh filtered air in. Both run continuously — no cycling, no reversal.

Cross-flow heat exchanger

Inside the unit, the supply and exhaust air streams pass each other at right angles through a heat exchanger. Heat transfers from outgoing to incoming air through the exchanger plates. The two streams never mix, but 87% of the heat does.

Sensors built into the device

CO₂, temperature, and humidity sensors sit inside the unit at intake. The X-Flow reads room conditions in real time and ramps airflow up or down automatically — no separate sensors to wire, no app required.

Filter

ePM 10-70% filter on the supply side — captures pollen, fine dust, and particulates 70% efficient at PM10 size. The highest filtration grade in the inVENTer range. Indoor and outdoor air filters, both replaceable from the unit front.

On-device touchpad

All controls live on the device front: automatic mode, manual mode, boost, and pause. No separate wall controller, no app, no pairing. The unit calibrates its own airflow automatically during commissioning.

Auto-close flaps

When the unit pauses or powers off, internal flaps close on both supply and exhaust to prevent draughts and stop outdoor air infiltrating the room. Closed-state air-tightness is part of the engineering, not an accessory.

Airflow 35–300 m³/h 35–300 m³/h continuous bidirectional. Both supply and exhaust streams running simultaneously through the cross-flow exchanger. 60% more capacity than X-Flow standard.
Heat recovery 87% Cross-flow plate exchanger. 87% of room heat retained. Air streams cross at right angles — heat transfers but air streams don't mix.
Sound level 12–32 dB 12–32 dB(A) at 2 m, measured to ISO 3744. Lowest setting comparable to a whisper.
Energy class A A. ErP / Ecodesign rated. Specific power 0.15 W/(m³/h), standby consumption <1 W.
Max power 33.4 W 33.4 W max at full boost. Standby <1 W. Powered via standard 230V outlet.
Capacity uplift 300 m³/h 300 m³/h max airflow — 60% more capacity than X-Flow standard. Suited to large open-plan apartments, commercial offices, restaurants, retail showrooms, and high-occupancy spaces.
Wall opening 2× Ø180 mm 2× Ø180 mm core holes through external wall. Two R-D160 sleeves with light weather grilles externally. Sleeve length 495 mm or 745 mm depending on wall depth.
Tower size 520×1945 mm 520 × 1945 × 202 mm (W × H × D). 40 kg. Floor-standing against external wall. Filter ePM 10-70%, sensors CO₂ + temperature + humidity.

Control

All controls live on the device front. No wall controller to wire, no app required. The X-Flow reads room conditions in real time and runs itself automatically — manual override always available.

On-device touchpad

Capacitive touchpad on the front of the unit. Selects operating mode, displays current airflow and sensor readings. No external wall controller required.

Automatic mode

The default. Unit reads CO₂, temperature, and humidity continuously and adjusts airflow to keep room conditions in the comfort zone. Cooking, hosting, working — the unit responds.

Manual mode

Override automatic behaviour and set airflow level directly at the touchpad. Useful when you want predictable airflow regardless of sensor readings — e.g. during long video calls or focused work.

Boost mode

Maximum airflow at 300 m³/h for clearing odours, post-cooking, or rapid air change after gatherings. Returns to automatic mode after the timed cycle.

Pause mode

Temporarily stop ventilation. Internal flaps close automatically to prevent draughts. Auto-resumes at the previously set mode after a configurable interval.

CO₂ sensor

Built-in CO₂ sensor reads room concentration in real time. Drives automatic boost when readings exceed comfort threshold (typically 1000 ppm). The most useful sensor in occupied rooms.

Humidity sensor

Built-in humidity sensor triggers automatic ramp-up when humidity rises — e.g. cooking steam, drying laundry, or exercise classes. No separate humidistat needed.

Temperature sensor

Built-in temperature sensor influences automatic mode. Ensures the unit doesn't pull excessive cold air into the room during winter or excessive heat during summer.

Auto-shutter flaps

When the unit pauses or powers down, internal flaps close automatically on supply and exhaust ducts to prevent draughts and stop outdoor air infiltrating the room.

Installation

Two wall holes, two sleeves, then position the tower against the external wall and plug into a 230V outlet. Commissioning happens at the on-device touchpad.

01 Consultation Free · phone or video Discuss the room — large open-plan space, commercial unit, design studio. Confirm 300 m³/h capacity matches the room volume and use pattern. Establish where the tower will sit and which external wall section can take two Ø180 mm core holes.
02 Survey 45 mins on site Mark drill locations, check for cables/pipes with detector. Confirm wall depth suits R-D160 sleeve length (495 mm or 745 mm). Agree exact tower position — flush with wall, near 230V outlet, clear floor footprint of 540 × 250 mm.
03 Install Half day on site Core-drill two Ø180 mm openings, fit two R-D160 wall sleeves with light weather grilles externally. Position tower against the wall, connect ducts to sleeves, plug into 230V outlet. Tower stands flat against the wall.
04 Commission 30 mins Power on. Configure operating mode at the touchpad — automatic is the default. Set CO₂ threshold to suit room use. Demonstrate touchpad operation, show filter cleaning. Hand over.

Components

A self-contained floor-standing tower with everything inside the casing. Two wall holes carry the supply and exhaust air to and from outside.

Tower dimensions

520 × 1945 × 202 mm (W × H × D). 40 kg. Floor-standing against an external wall — height roughly equivalent to a designer radiator. Sits flat against the wall.

Wall openings

Two Ø180 mm core holes through the same external wall — one for supply air, one for exhaust. Spaced for thermal separation and routed to the unit through R-D160 wall sleeves.

R-D160 wall sleeves

Two R-D160 sleeves fit into the wall openings. Includes light weather-protection grilles externally (RAL 9010 white) — flush with facade, no protruding hood.

Cross-flow heat exchanger

Plate exchanger inside the tower. Supply and exhaust streams cross at right angles through metal plates. 87% heat recovery, no air mixing. No moving parts in the exchanger itself.

Integrated supply & exhaust fans

Two integrated fans — one for supply, one for exhaust — running continuously. Lower speed, lower noise per cubic metre than reversing fans. ePM 10–70% filter on the supply side.

Indoor and outdoor air filters

Two filters: one filters the incoming outdoor air (ePM 10–70%), the other filters the outgoing indoor air to protect the heat exchanger. Both replaceable from the front of the unit.

Sensor module

CO₂, temperature, and humidity sensors integrated into the unit. Measure room conditions at intake and feed automatic control logic in real time.

Touchpad & control unit

Capacitive touchpad on the front of the unit. Selects mode, displays sensor readings and current airflow. Pre-installed connection cable plugs into a standard 230V outlet.

Auto-shutter flaps

Internal flaps on supply and exhaust ducts. Close automatically when the unit pauses or shuts down — no draughts during pause, no thermal bridge through the wall openings when off.

Aftercare

The X-Flow has more components than a wall MVHR — two filters and a sensor module — but the maintenance load is still low. Filter changes every 6 months and a CO₂ sensor recalibration once a year are the only routine tasks.

5 year warranty

inVENTer covers the unit for 5 years from commissioning. Manufactured in Germany since 1999. ISO 9001 quality system, full CE conformity.

Filter changes

Two filters: incoming ePM 10-70% and outgoing protection filter. Both replaceable from the front of the unit. Recommended every 6 months in residential, 3 months in high-occupancy or polluted environments.

CO₂ sensor recalibration

CO₂ sensor benefits from annual recalibration to a known fresh-air baseline. Done by opening windows fully for 30 minutes and triggering calibration mode at the touchpad. Takes 5 minutes.

Heat exchanger inspection

Cross-flow exchanger plates can be removed and rinsed once a year if needed. Most installations don't need this — the protection filter keeps the exchanger clean.

No service contract

No annual servicing required. No smart subscriptions, no remote monitoring fees. The unit just runs.

No refrigerant

Purely mechanical — fans, plate exchanger, no F-gas. No regulated handling, no leak risk, no phase-out concerns.

Pricing

Transparent pricing.
Grant included.

Heat pump unit only. Radiators, UFH, and emitters are on the heating page.

No items found.
fully installed
supply only

£3,284

Equipment only · no installation


What's included

X-Flow Plus tower — single unit £3,284
2× R-D160 wall sleeves with light weather grilles included
Built-in CO₂, temperature, humidity sensors · on-device touchpad · auto-shutter flaps · cross-flow heat exchanger · ePM 10–70% filter —

Optional add-ons

Replacement filter set (annual) +£45
Spare ePM 10–70% filter +£25
Equipment total £3,284

£3,784

Fully installed · equipment + installation & commissioning


What's included

X-Flow Plus tower — single unit £3,284
2× R-D160 wall sleeves with light weather grilles included
Built-in CO₂, temperature, humidity sensors · on-device touchpad · auto-shutter flaps · cross-flow heat exchanger · ePM 10–70% filter —
Installation & commissioning £500

Optional add-ons

Replacement filter set (annual) +£45
Spare ePM 10–70% filter +£25
Fully installed total £3,784

£3,284

Equipment only · no installation


What's included

X-Flow Plus tower — single unit £3,284
2× R-D160 wall sleeves with light weather grilles included
Built-in CO₂, temperature, humidity sensors · on-device touchpad · auto-shutter flaps · cross-flow heat exchanger · ePM 10–70% filter —

Optional add-ons

Replacement filter set (annual) +£45
Spare ePM 10–70% filter +£25
Equipment total £3,284
Equipment
£11,200
Installation & commissioning
£4,300
Fully installed
£15,500
After £7,500 BUS grant 0% VAT until March 2027
£8,000
get a quote
Whats App instead
No items found.

Technical specifications

Airflow 35–300 m³/h 35–300 m³/h continuous bidirectional. Both supply and exhaust streams running simultaneously through the cross-flow exchanger. 60% more capacity than X-Flow standard.
Heat recovery 87% Cross-flow plate exchanger. 87% of room heat retained. Air streams cross at right angles — heat transfers but air streams don't mix.
Sound level 12–32 dB 12–32 dB(A) at 2 m, measured to ISO 3744. Lowest setting comparable to a whisper.
Energy class A A. ErP / Ecodesign rated. Specific power 0.15 W/(m³/h), standby consumption <1 W.
Max power 33.4 W 33.4 W max at full boost. Standby <1 W. Powered via standard 230V outlet.
Capacity uplift 300 m³/h 300 m³/h max airflow — 60% more capacity than X-Flow standard. Suited to large open-plan apartments, commercial offices, restaurants, retail showrooms, and high-occupancy spaces.
Wall opening 2× Ø180 mm 2× Ø180 mm core holes through external wall. Two R-D160 sleeves with light weather grilles externally. Sleeve length 495 mm or 745 mm depending on wall depth.
Tower size 520×1945 mm 520 × 1945 × 202 mm (W × H × D). 40 kg. Floor-standing against external wall. Filter ePM 10-70%, sensors CO₂ + temperature + humidity.

Works with

No items found.

Installed by CleverBloom

No items found.

About products

arrow

Heading 1

Heading 2

Heading 3

Heading 4

Heading 5
Heading 6

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur.

Block quote

Ordered list

  1. Item 1
  2. Item 2
  3. Item 3

Unordered list

  • Item A
  • Item B
  • Item C

Text link

Bold text

Emphasis

Superscript

Subscript

line

Request a Service

Call us at 07526 985258

or leave your contact information below,
and we'll get back to you soon.

Thank you! Your message has been sent. We’ll get back to you soon!
Oops! Something went wrong. Please try again or check your details and submit again.

Ready for a better building?

Join our certified installer network — leads, products, and technical support provided.

Whats App instead
Clever Bloom - Smart Home and MVHR Ventilation Installation UK

We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.

Working hours: Mon - Sun. 8am - 8pm

Proudly serving the entire UK!

Give us a call
07526 985258
Send us an email
info@cleverbloom.co.uk
Technology catalog
AirHeatingCoolingHumidityWaterEnergyInsulation
Company
ProjectsBecome an installer
Social media
InstagramFacebooklinkedin
Documents
Privacy policyTerms and conditions
Location
Address: 3 Vickers house,  3 Hornchurch road UB10 0YG, London

© 2026 Clever Bloom — All rights reserved

Company registered in England and Wales / Company number: 14242566.