We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.
Working hours: Mon - Sun. 8am - 8pm
Proudly serving the entire UK!
Company
NHS HTM COMPLIANT
Low Surface Temperature radiator
Casing stays ≤ 43°C
SAFE EVEN IF A CHILD OR VULNERABLE ADULT LEANS AGAINST IT
Approved for healthcare
NHS ESTATES HTM GUIDANCE · BUILDING REGS DOC M
Heat-pump ready
LOW-WATER RADIATOR THAT WORKS AT LOW FLOW TEMPERATURES
Fast install
15 MINUTES BY ONE INSTALLER · NOT TWO
Heats up quickly
90% LESS WATER THAN STEEL PANEL · WARM FAST
10% energy saving
VS EQUIVALENT STEEL PANEL RADIATORS (BRE VERIFIED)
30-year warranty
ON THE LOW-H2O HEAT EXCHANGER
Wall or floor
WALL-MOUNTED OR FLUSH-TO-FLOOR VERSIONS
Hot water from your boiler or heat pump flows through a small heat exchanger inside the casing. Just like a normal radiator — the difference is what surrounds the heat exchanger.
Cool air enters through the bottom grille, passes over the warm heat exchanger, and leaves through the top grille. The heat exchanger never gets touched. The casing stays at a safe temperature.
Even when the water inside is at 75°C (which can scald in seconds), the outside of the radiator never exceeds 43°C. Safe to lean against. Safe for children to touch. Compliant with NHS guidelines.
The Low-H2O heat exchanger contains 90% less water than a steel panel radiator. Less water means faster heat-up. Less wasted energy when you turn the heating up or off.
Older steel radiators need very hot water (65–75°C) to give enough heat. That's inefficient for heat pumps. Guardian LST works well at lower flow temperatures (35–45°C) — ideal for modern air-source or ground-source heat pumps.
Pipework connects inside the casing — no exposed hot pipes for anyone to touch or knock. Casing locks come as standard so no one can open it without a key.
The radiator is controlled the same way as any wet-system radiator — via your existing boiler or heat pump and a thermostatic valve.
Thermostatic valve (TRV)
A small dial on the radiator’s pipework controls how much hot water flows through. Set it once for the room temperature you want — the radiator does the rest automatically. The valve sits inside the casing for safety.
Concealed valve option
For care homes and schools, the valve can be locked behind the casing so residents or children can’t change the temperature. Staff have the key.
Smart TRV (optional)
Replace the standard dial with a smart TRV controlled by your phone or central thermostat. Set weekly schedules per room. Pairs with most smart heating systems.
Central thermostat compatible
Works with your existing wall thermostat — Nest, Hive, Tado, or a simple programmer. No special controls needed for Guardian LST specifically.
Pencil-proof grilles
Optional grille upgrade with smaller openings — stops residents in care homes pushing pencils or fingers into the radiator.
CleverBloom can help
If you want help choosing controls or pairing with your existing heating system, the engineer sorts it on the day. Or call us anytime.
The fastest LST radiator to install in the UK. 15 minutes per radiator by a single installer.
What’s inside the Guardian LST — the parts that make a safe, NHS-compliant radiator with a 30-year warranty.
1 · Low-H2O heat exchanger
A small aluminium-and-copper coil — holds 90% less water than a steel panel radiator. Hot water from your boiler or heat pump flows through it. The 30-year warranty covers this part.
2 · One-piece outer casing
Powder-coated steel casing surrounds the heat exchanger. The visible outer surface never exceeds 43°C — safe to lean against. Available in white, sandblast grey, or off-black as standard. Lightweight enough for a single installer.
3 · Rounded corners
The casing has rounded edges and a chamfered profile — no sharp corners. Designed specifically for healthcare and care-home environments where residents and patients may bump into furniture.
4 · Casing locks (standard)
The front panel is locked to the wall bracket with allen-key fixings. Stops residents, patients, or children from opening the casing. Standard on every Guardian LST.
5 · Top grille
Warm air leaves the radiator through the top grille. Optional pencil-proof version with smaller holes is available for care homes and schools — stops curious fingers or objects entering the casing.
6 · Concealed valves and pipework
The valves and pipes that connect to your heating system are hidden inside the casing — no exposed hot pipes for anyone to touch or knock. TRV optional on the valve for room-temperature control.
7 · Wall brackets
Two lightweight steel brackets fix to the wall. The casing then slides on and locks. One installer can fit it in 15 minutes — half the time of equivalent steel-panel LST radiators.
8 · CleverBloom can help
For care homes, schools, or NHS settings, we specify the right Guardian LST configuration (with or without pencil-proof grille, with or without TRV lock) during the site survey.
Guardian LST is designed for commercial-grade duty cycles. Almost nothing to maintain.
30-year heat-exchanger warranty
The Low-H2O heat exchanger inside the radiator is warranted for 30 years — one of the longest in the UK heating industry. Most boilers will need replacing several times in that period.
Built in Belgium
Made by Jaga at their Diepenbeek, Belgium factory. Jaga has been building radiators since 1962. The Low-H2O exchanger is their patented design.
Wipe clean
Powder-coated casing wipes clean with a soft damp cloth. The casing locks let staff open the radiator for inside cleaning if dust builds up over years.
No bleeding service
The radiator is bled once at install and stays balanced. No annual bleeding routine for housekeeping staff to remember.
Service plan available
For multi-unit installations in care homes or schools, CleverBloom offers annual maintenance contracts covering all radiators on one visit.
No VAT on the install
UK government has removed VAT on heating installs until March 2027 when paired with energy-saving systems like heat pumps. CleverBloom handles the paperwork.
Heat pump unit only. Radiators, UFH, and emitters are on the heating page.
-
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur.
Block quote
Ordered list
Unordered list
Bold text
Emphasis
Superscript
Subscript

_11zon%20(1).webp)
Call us at 07526 985258
or leave your contact information below,
and we'll get back to you soon.
Join our certified installer network — leads, products, and technical support provided.
We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.
Working hours: Mon - Sun. 8am - 8pm
Proudly serving the entire UK!
© 2026 Clever Bloom — All rights reserved
Company registered in England and Wales / Company number: 14242566.