Clever Bloom - Smart Home and MVHR Ventilation Installation UKClever Bloom - Smart Home and MVHR Ventilation Installation UK
  • Solutions
    • Air
    • Heating
    • Water Treatment System
    • EV charger
    • Smart home
  • Join us
  • Ventilation Applications

Solutions

  • Air
  • Heating
  • Ev Charger
  • Smart Home
  • Water Treatment Systems

Information

  • Ventilation Applications
  • Join Us

Working hours: Mon - Sun. 8am - 8pm

Proudly serving the entire UK!

Free consultation on WhatsApp
07526 985258
  • Home
  • /
  • Air
  • /
  • Nilan Compact P
Active heat recovery via heat pump
Reversible cooling · up to 10°C
Modbus TCP/IP + RS485 + Nilan app
CTS602 touch HMI control

Nilan Compact P

Ventilation + heating + cooling + 180L hot water · Single appliance · No outdoor unit required

140m²
low-energy floor area
275m³/h
max airflow
95%
passive heat recovery
180L
hot water tank
3:1
heat pump COP
PHI
Passivhaus certified
get a quote
Whats App instead
Why switch

Why this compact service unit

95% counterflow heat recovery

EN 308 / EN 13141-7 verified · among the highest in compact service unit category

PHI Passivhaus Institut certified

Cool temperate climates · among the few compact systems with PHI certified component status worldwide

Range scales to 200+ m²

Compact P → Air9 (waterborne UFH) → Geo (ground source) → XL (multi-unit, 430 m³/h)

Active heat recovery

Heat pump recovers the final 5–10% energy passive exchanger leaves behind · COP 3:1 average

Reversible cooling · up to 10°C

Heat pump runs in reverse to dehumidify and cool supply air · waste heat goes to hot water

Established UK market presence

16+ years of UK installs · A2Dominion Southall · widely recognised by SAP assessors and Passivhaus consultants

CTS602 control · Modbus + Nilan app

HMI touch panel · Modbus TCP/IP + RS485 RTU · iOS / Android remote monitoring

No outdoor unit · single appliance

Replaces MVHR + heat pump + DHW cylinder · simpler architecture · no condenser to plan around

How it works
Specification
Control/App
Installation
components
Aftercare

Two-stage heat recovery

Compact P uses both passive and active heat recovery in series. First, a high-efficiency counterflow heat exchanger captures up to 95% of heat from extract air and transfers it to incoming fresh air without mixing the two streams. Then the integrated heat pump recovers the residual 5–10% energy that the passive exchanger cannot — combining for effectively complete heat recovery from extract air. This is what Nilan call "active heat recovery", and it's the architectural difference vs simpler MVHR units.

Hot water from extract air

When the supply air temperature setpoint is met, the heat pump diverts its output to the 180-litre integrated hot water tank instead. Extract air is the heat source — typical exhaust air at 20–22°C provides reliable heat pump performance year-round, much more stable than ambient outdoor air. COP for hot water is approximately 3:1 — three units of heat per unit of electrical input. Continuous ventilation operation means continuous low-cost hot water production.

Reversible cooling cycle

In summer, the heat pump runs in reverse — supply air is cooled by up to 10°C below outdoor air temperature, while waste heat from the cooling cycle goes to top up the hot water tank. Free hot water during cooling season. Note: this is supplementary cooling for low-energy buildings, not air conditioning. The low ventilation rate (275 m³/h max) is sized for fresh air, not for active room cooling like a split AC unit.

Summer bypass · free cooling

When outdoor air is cooler than indoor (typical UK summer nights), the bypass damper routes incoming fresh air around the heat exchanger rather than through it. Cool night air enters the home directly without being warmed by extract air. Free cooling, no heat pump electricity needed. Combined with the active reversible cooling for hot days, gives the homeowner two cooling strategies — passive bypass when outdoor is favourable, active heat pump when not.

Polar variant · cold climate

For cold-climate installations (highland Scotland, Cumbria, exposed sites), Compact P Polar adds an integrated electric pre-heater on the outdoor air intake. This prevents ice formation in the heat exchanger during severe frost, maintaining full heat recovery throughout winter rather than dropping into defrost cycles. Standard Compact P uses an automatic defrost cycle when frost is detected — cheaper, but with brief efficiency dips during defrost. Specified at order based on site exposure.

Range scaling · AIR9 / GEO / XL

For projects beyond standard Compact P scope: AIR9 adds an integrated air-to-water heat pump (~9 kW) for waterborne UFH or radiator heating — scales the system into 200+ m² family Passivhaus territory. GEO 3 / 6 / 9 variants add ground-source heat pumps for waterborne heating. XL variant scales airflow to 430 m³/h for larger or multi-unit dwellings. All share the same control architecture, hot water tank, and ventilation core.

Coverage 140 m² Up to 140 m² low-energy floor area. Suitable for apartments, small houses, mews infill, compact Passivhaus. AIR9 / GEO variants scale to 200+ m². XL scales airflow for larger or multi-unit dwellings up to 430 m³/h.
Airflow 275 m³/h 50 to 275 m³/h variable. Reference flow for sound and efficiency data 265 m³/h at 250 Pa external pressure. EC fan motors with variable speed control. SEL/SFP values per Nilan planning data sheet.
Heat Recovery 95% Up to 95% temperature efficiency on the counterflow heat exchanger alone (passive). Active heat recovery via integrated heat pump captures the residual energy that the passive exchanger leaves behind — combining for effectively complete heat recovery from extract air. Per EN 308 / EN 13141-7.
Heating COP 3:1 Air-to-air heat pump heats the supply air via active heat recovery. COP 3:1 average — three units of heat output per unit of electrical input. Heat output per EN 14511 (t11=21°C extract air). For waterborne heating (UFH, radiators), specify Compact P AIR9 or GEO variant — see Configuration tab.
Cooling −10°C Reversible cooling cycle — supply air cooled by up to 10°C below outdoor temperature. Waste heat from cooling cycle goes to top up the hot water tank — free hot water during cooling season. Note: not air conditioning. The 275 m³/h ventilation rate is sized for fresh air, not active room cooling.
Hot Water 180 L 180L integrated tank. Tapped volume 220L of 40°C water at 50°C tank setpoint. Heat pump uses extract air as the heat source — stable 20–22°C source year-round. Automatic weekly anti-legionella boost above 60°C. Electronically monitored sacrificial anode with replacement alarm. Built-in scalding protection at the tap.
Refrigerant Sealed Hermetically sealed cooling circuit. Modern Compact P models specified to current Nilan refrigerant standard — confirmed at order against latest UK F-gas regulations. Nilan publishes EU Ecodesign Directive compliant refrigerant data sheets per variant.
Electrical 230V · 1ph 230V single-phase, 50 Hz. EC fan motors. Hermetically-sealed compressor. 2 × 2 kW electric auxiliary heating elements (1 in tank, 1 in air supply for boost / frost protection). Standard mains supply, no 3-phase distribution required. RCD per UK Building Regulations.
Filtration F7 option Standard ISO Coarse / G4-equivalent filters (75% pollen, dust, soot capture). Optional F7 fine particulate filters (ePM1 70%) for allergy-sensitive households or high-pollution urban installs. Front-loading access. Filter timer 30–180 days, automatic CTS602 alarm.
Acoustic Insulated Sound data referenced at 275 m³/h and 100 Pa external per EN 9614-2 (surface) and EN 5136 (ducts). Sound power drops with falling air volume and reduced back-pressure. Sound-insulated panels in the cabinet keep plant-room emission low for installs adjacent to bedrooms.
Form Factor Vertical Vertical floor-standing cabinet. Designed for plant rooms, utility cupboards, or boiler-room replacement. Compact S variant only 600mm wide for space-constrained installs. Compact P EK wall-mounted variant 590 × 762 × 612 mm (MVHR-only, no tank). All variants engineered for tight UK installs.
Certification PHI Passivhaus Institut PHI Certified Component for cool temperate climates — among only a handful of compact systems certified worldwide. EU Ecodesign Directive compliant. UK installations include A2Dominion Southall and other Passivhaus and Future Homes Standard schemes.

Control

Compact P ships with the CTS602 control system as standard — HMI Touch panel, integrated humidity sensor, automatic legionella protection, weekly schedule programming, and intelligent humidity control. Modbus TCP/IP and RS485 RTU as standard for BMS integration. Nilan app for iOS and Android. Optional CO₂ sensor, external HMI panel, and remote service portal.

CTS602 HMI Touch panel

Standard Nilan control system with HMI Touch panel — graphical interface for ventilation steps, temperature setpoints, hot water schedule, and humidity control. Wall-mountable in living space or utility room. Multi-language support including English. Visual filter change reminder, alarm log, and energy consumption monitoring.

Nilan app · iOS / Android

Free Nilan mobile app for remote monitoring and control. Adjust ventilation step, change hot water setpoint, view alarm status, and monitor system performance — at home or away. Filter change reminders pushed to the app automatically when due. Single account supports multiple buildings — useful for landlords or property managers.

Nilan service portal

Optional remote service portal for ongoing monitoring by property managers, landlords, or maintenance teams. Diagnose issues remotely without site visit. Particularly useful for multi-unit residential developments — A2Dominion-style schemes where one operator manages dozens of Compact P installs across a development.

Modbus TCP/IP + RS485

Open Modbus communication standard — both TCP/IP (Ethernet) and RS485 RTU (serial) supported. Bidirectional — BMS can monitor every parameter and write settings, not just read status. Direct integration with Loxone, KNX (via gateway), Crestron, Niagara, or any Modbus-compatible BMS. Default protocol set to Modbus TCP/IP.

Intelligent humidity control

Built-in humidity sensor on the extract air circuit. CTS602 controller automatically increases ventilation when humidity rises (showers, cooking) and reduces ventilation in winter when indoor air is too dry. Adjustable threshold per room or whole-house. Reduces condensation risk and improves comfort without manual intervention. Standard on every Compact P.

CO₂ sensor (optional)

Optional Korea Digital SenseCube CO₂ sensor for demand-controlled ventilation. Increases airflow when occupancy raises CO₂ levels, drops to baseline when room is empty. NDIR dual-wavelength sensor, RS485 / 4–20mA / 0–10V outputs. Most useful for variable-occupancy spaces — guest rooms, home offices, multi-unit residential.

Automatic legionella protection

CTS602 automatically boosts hot water tank temperature above 60°C once weekly via the integrated electric immersion heater — kills any legionella build-up in the tank. Standard on every Compact P. Built-in scalding protection prevents output above safe temperature at the tap. Electronically monitored sacrificial anode with alarm when replacement is due.

User select + cooker hood interlock

Programmable user selection inputs accept potential-free signals from cooker hoods, fireplaces, or external switches. Cooker hood input automatically increases extract airflow when hood runs — protects negative pressure balance. Output signal can drive a damper. CTS602 can be programmed for multi-zone Passivhaus operation including night setback and away mode.

Installation

Compact P is a Passivhaus-class plant unit best specified at the new-build design stage or as part of a deep retrofit / EnerPHit project. Typical sequence: design + sizing 4–6 weeks ahead; first-fix during construction; plant install in finished plant room; commissioning and handover with full CTS602 setup and Nilan app pairing.

01 Design + Nilan sizing 4–6 weeks before site Floor area, occupancy, hot water demand, and architectural layout reviewed. Compact P or AIR9 / GEO / XL variant specified based on m², heating distribution preference (air-only or waterborne), and project brief. Polar variant chosen if cold-climate exposure. Outdoor and exhaust air route designed (roof, façade, or wall). Order placed via Nilan UK. Lead time confirmed at order — typically 6–8 weeks from Denmark.
02 First-fix + ductwork During construction Plant room positioned per design. Outdoor and exhaust air ducts run to chosen termination point. Supply and extract ductwork run to all habitable rooms — supply to bedrooms and living, extract from kitchens and bathrooms. Single-phase 230V circuit run to plant room with appropriate RCD. Cold water inlet, hot water flow/return, condensate drain. Modbus / Ethernet cabling to BMS or local network if specified.
03 Plant install 1 day on site Compact P delivered on a pallet — vertical floor-standing unit. Lifted into final plant-room position. Connections made to ductwork, DHW inlet/outlet, cold water, condensate drain, and electrical supply. HMI Touch panel mounted in living space and connected via low-voltage cabling. AIR9 / GEO outdoor unit positioned outside if specified.
04 Commissioning + handover 1 day on site Initial power-up. CTS602 controller configured — ventilation steps, hot water schedule, humidity setpoints, weekly programming. Active heat recovery balanced and verified. Reversible cooling tested. Nilan app paired to homeowner's network. Modbus / Ethernet integration with BMS verified. Filter timer started. CleverBloom hands over Building Regulations Part F commissioning certificate, Nilan O&M documentation, and service plan options.

Configuration & sizing

Compact P is a family of variants covering everything from compact apartments to family Passivhaus to multi-unit developments. Each variant shares the core 180L hot water tank, CTS602 control, and counterflow heat exchanger architecture — but adds different heating capabilities and capacity points to suit project scope.

Compact P — anchor configuration

Up to 140 m² low-energy floor area, ventilation requirement up to 275 m³/h. 95% counterflow heat recovery (passive) plus active heat recovery via integrated heat pump. 180L hot water tank. Reversible cooling cycle. CTS602 control with HMI Touch panel. Single-phase 230V. Vertical floor-standing cabinet. The default specification for typical apartment, small house, or compact Passivhaus.

Compact S — narrow variant

Same architecture as Compact P in a 600mm-wide cabinet — 30% narrower than the standard P. The right pick for tight plant cupboards, mews infill, or apartment installs where space is constrained. Same 180L tank, same heat recovery efficiency, same control system. Slightly reduced max airflow at 375 m³/h. Quote on request.

Compact P EK — wall-mounted

Wall-mounted compact variant for installations where floor space is at a premium. 590 × 762 × 612 mm, only 38 kg, fits into false ceilings or above kitchen cabinets. Up to 180 m² coverage, 70–300 m³/h airflow. Sound levels 21–44 dB(A). Note: this variant is MVHR-only (no heat pump or hot water tank) — different scope to the Compact P range. Quote on request.

Compact P Polar — cold climate

Standard Compact P with integrated electric pre-heater on the outdoor air intake — protects the heat exchanger from icing during severe frost. Maintains full heat recovery at -15°C and below. The right pick for highland Scotland, exposed Cumbrian sites, and projects above 200m elevation where standard defrost cycles would impact comfort. Quote on request.

Compact P AIR9 — waterborne heating

Compact P with integrated air-to-water heat pump (~9 kW output) for waterborne heating to underfloor heating, radiators, or low-temperature heating circuits. Outdoor unit included. Scales the system into 200+ m² family Passivhaus territory where air-only heating would not be enough. The right pick when project brief specifies UFH or radiators. Quote on request.

Compact P GEO 3 / 6 / 9 — ground source

Compact P with integrated geothermal heat pump (3 kW, 6 kW, or 9 kW output variants) for waterborne heating from buried earth tubes or boreholes. Highest seasonal efficiency available — ground temperature is more stable than air. Right pick for rural plots with land for ground loops, and for clients prioritising long-term energy bills over capital cost. Quote on request.

Compact P XL — large dwellings

Higher-rated fans for larger family Passivhaus or multi-unit installations — 430 m³/h max airflow vs 275 m³/h on standard P. Same modular architecture, same heat recovery, same hot water tank. Combines with AIR9 or GEO modules for waterborne heating. Right pick for 4+ bedroom Passivhaus, multi-occupancy schemes, or commercial offices with elevated fresh-air demand. Quote on request.

Filter upgrade options

Standard ISO Coarse / G4-equivalent filters fitted (75% pollen, dust, soot capture). Optional upgrade to F7 fine particulate filters (ePM1 70%) for households with allergy or asthma sensitivity, or installs in high-traffic urban areas (London, motorway proximity). Front-loading filter access — homeowner-replaceable in 5 minutes. CTS602 flags filter change automatically.

Aftercare

Compact P is designed for long service life — typically 15–20+ years of continuous operation. Filter changes and anode monitoring are routine; refrigerant circuit is sealed for life. Nilan manufacturer warranty + CleverBloom service plan together provide the support architecture for high-spec self-build, EnerPHit, and multi-unit residential clients.

Nilan manufacturer warranty

Standard Nilan manufacturer warranty applies — typically 2 years on full unit with extended coverage on heat pump and major components. Terms confirmed at order against current Nilan general conditions. Compact P installs covered through Nilan UK / Project Ziro Ltd, with their service portal supporting fault diagnosis and warranty claims directly.

Filter change · adjustable schedule

CTS602 filter timer adjustable from 30 to 180 days. Automatic alarm when filters due. Front-loading access via top front panel — homeowner-replaceable in 5 minutes, no tools. Standard ISO Coarse / G4 filters, optional F7 upgrade for allergy-sensitive households or high-pollution urban installs. Genuine Nilan replacement filters via Nilan UK service portal.

Electronically monitored anode

Sacrificial anode in the 180L hot water tank with electronic monitoring — CTS602 alarms when replacement is due (typically 5–10 years depending on water chemistry). Unlike unmonitored anodes that fail silently and damage the tank, the alarm prevents corrosion. Hard water areas may need more frequent replacement; soft water areas extend service life.

Automatic anti-legionella cycle

CTS602 boosts the hot water tank temperature to over 60°C automatically once weekly via the integrated immersion heater — kills any legionella that could grow during normal operation at 45–50°C. Required for Building Regulations Part G compliance. Boost cycle runs at off-peak hours to minimise electricity cost. No homeowner action needed.

Heat exchanger maintenance

The plastic counterflow heat exchanger requires no defrosting or active maintenance — it operates independently. Annual visual check during service visits to confirm no debris build-up, but typically clean for the life of the unit. Compact P Polar variant adds the pre-heater coil which is also maintenance-free.

CleverBloom Passivhaus service plan

For Compact P installs, CleverBloom offers an annual service plan covering: filter changes (parts and labour), anode status verification, control parameter review, ventilation airflow re-balance check, Nilan app account audit, and CTS602 firmware version review. Quoted per project based on access and SLA requirements. Multi-unit residential pricing available.

Pricing

Transparent pricing.
Grant included.

Heat pump unit only. Radiators, UFH, and emitters are on the heating page.

No items found.
fully installed
supply only

POA

Equipment only · up to 140 m² · 275 m³/h · 180L hot water · PHI certified · ex VAT


What's included

Includes Nilan Compact P unit (vertical floor-standing cabinet), counterflow heat exchanger (95% passive recovery), integrated air-to-air heat pump, 180L hot water tank with electronically monitored anode, CTS602 control with HMI Touch panel, EC fan motors, ISO Coarse / G4 filters, Modbus TCP/IP + RS485 RTU interface, Nilan app pairing, hermetically sealed refrigerant circuit, manufacturer warranty registration, and carriage from Denmark to UK site POA

Variants & sizing alternatives

Compact S (narrow 600mm cabinet) POA
Compact P EK (wall-mounted, MVHR-only) POA
Compact P Polar (cold climate pre-heater) POA
Compact P AIR9 (waterborne UFH/radiators) POA
Compact P GEO 3 / 6 / 9 (ground source heat pump) POA
Compact P XL (430 m³/h, large dwellings) POA
F7 fine particulate filter upgrade POA
CO₂ sensor for demand-controlled ventilation POA
Equipment total ex VAT POA

POA

Fully installed · equipment + design, first-fix & install


What's included

Includes Nilan Compact P unit (vertical floor-standing cabinet), counterflow heat exchanger (95% passive recovery), integrated air-to-air heat pump, 180L hot water tank with electronically monitored anode, CTS602 control with HMI Touch panel, EC fan motors, ISO Coarse / G4 filters, Modbus TCP/IP + RS485 RTU interface, Nilan app pairing, hermetically sealed refrigerant circuit, manufacturer warranty registration, and carriage from Denmark to UK site POA
Design + first-fix + install POA

Variants & sizing alternatives

Compact S (narrow 600mm cabinet) POA
Compact P EK (wall-mounted, MVHR-only) POA
Compact P Polar (cold climate pre-heater) POA
Compact P AIR9 (waterborne UFH/radiators) POA
Compact P GEO 3 / 6 / 9 (ground source heat pump) POA
Compact P XL (430 m³/h, large dwellings) POA
F7 fine particulate filter upgrade POA
CO₂ sensor for demand-controlled ventilation POA
Project total POA

POA

Equipment only · up to 140 m² · 275 m³/h · 180L hot water · PHI certified · ex VAT


What's included

Includes Nilan Compact P unit (vertical floor-standing cabinet), counterflow heat exchanger (95% passive recovery), integrated air-to-air heat pump, 180L hot water tank with electronically monitored anode, CTS602 control with HMI Touch panel, EC fan motors, ISO Coarse / G4 filters, Modbus TCP/IP + RS485 RTU interface, Nilan app pairing, hermetically sealed refrigerant circuit, manufacturer warranty registration, and carriage from Denmark to UK site POA

Variants & sizing alternatives

Compact S (narrow 600mm cabinet) POA
Compact P EK (wall-mounted, MVHR-only) POA
Compact P Polar (cold climate pre-heater) POA
Compact P AIR9 (waterborne UFH/radiators) POA
Compact P GEO 3 / 6 / 9 (ground source heat pump) POA
Compact P XL (430 m³/h, large dwellings) POA
F7 fine particulate filter upgrade POA
CO₂ sensor for demand-controlled ventilation POA
Equipment total ex VAT POA
Equipment
£11,200
Installation & commissioning
£4,300
Fully installed
£15,500
After £7,500 BUS grant 0% VAT until March 2027
£8,000
get a quote
Whats App instead
No items found.

Technical specifications

Coverage 140 m² Up to 140 m² low-energy floor area. Suitable for apartments, small houses, mews infill, compact Passivhaus. AIR9 / GEO variants scale to 200+ m². XL scales airflow for larger or multi-unit dwellings up to 430 m³/h.
Airflow 275 m³/h 50 to 275 m³/h variable. Reference flow for sound and efficiency data 265 m³/h at 250 Pa external pressure. EC fan motors with variable speed control. SEL/SFP values per Nilan planning data sheet.
Heat Recovery 95% Up to 95% temperature efficiency on the counterflow heat exchanger alone (passive). Active heat recovery via integrated heat pump captures the residual energy that the passive exchanger leaves behind — combining for effectively complete heat recovery from extract air. Per EN 308 / EN 13141-7.
Heating COP 3:1 Air-to-air heat pump heats the supply air via active heat recovery. COP 3:1 average — three units of heat output per unit of electrical input. Heat output per EN 14511 (t11=21°C extract air). For waterborne heating (UFH, radiators), specify Compact P AIR9 or GEO variant — see Configuration tab.
Cooling −10°C Reversible cooling cycle — supply air cooled by up to 10°C below outdoor temperature. Waste heat from cooling cycle goes to top up the hot water tank — free hot water during cooling season. Note: not air conditioning. The 275 m³/h ventilation rate is sized for fresh air, not active room cooling.
Hot Water 180 L 180L integrated tank. Tapped volume 220L of 40°C water at 50°C tank setpoint. Heat pump uses extract air as the heat source — stable 20–22°C source year-round. Automatic weekly anti-legionella boost above 60°C. Electronically monitored sacrificial anode with replacement alarm. Built-in scalding protection at the tap.
Refrigerant Sealed Hermetically sealed cooling circuit. Modern Compact P models specified to current Nilan refrigerant standard — confirmed at order against latest UK F-gas regulations. Nilan publishes EU Ecodesign Directive compliant refrigerant data sheets per variant.
Electrical 230V · 1ph 230V single-phase, 50 Hz. EC fan motors. Hermetically-sealed compressor. 2 × 2 kW electric auxiliary heating elements (1 in tank, 1 in air supply for boost / frost protection). Standard mains supply, no 3-phase distribution required. RCD per UK Building Regulations.
Filtration F7 option Standard ISO Coarse / G4-equivalent filters (75% pollen, dust, soot capture). Optional F7 fine particulate filters (ePM1 70%) for allergy-sensitive households or high-pollution urban installs. Front-loading access. Filter timer 30–180 days, automatic CTS602 alarm.
Acoustic Insulated Sound data referenced at 275 m³/h and 100 Pa external per EN 9614-2 (surface) and EN 5136 (ducts). Sound power drops with falling air volume and reduced back-pressure. Sound-insulated panels in the cabinet keep plant-room emission low for installs adjacent to bedrooms.
Form Factor Vertical Vertical floor-standing cabinet. Designed for plant rooms, utility cupboards, or boiler-room replacement. Compact S variant only 600mm wide for space-constrained installs. Compact P EK wall-mounted variant 590 × 762 × 612 mm (MVHR-only, no tank). All variants engineered for tight UK installs.
Certification PHI Passivhaus Institut PHI Certified Component for cool temperate climates — among only a handful of compact systems certified worldwide. EU Ecodesign Directive compliant. UK installations include A2Dominion Southall and other Passivhaus and Future Homes Standard schemes.

Works with

No items found.

Installed by CleverBloom

No items found.

About products

arrow

Heading 1

Heading 2

Heading 3

Heading 4

Heading 5
Heading 6

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur.

Block quote

Ordered list

  1. Item 1
  2. Item 2
  3. Item 3

Unordered list

  • Item A
  • Item B
  • Item C

Text link

Bold text

Emphasis

Superscript

Subscript

line

Request a Service

Call us at 07526 985258

or leave your contact information below,
and we'll get back to you soon.

Thank you! Your message has been sent. We’ll get back to you soon!
Oops! Something went wrong. Please try again or check your details and submit again.

Ready for a better building?

Join our certified installer network — leads, products, and technical support provided.

Whats App instead
Clever Bloom - Smart Home and MVHR Ventilation Installation UK

We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.

Working hours: Mon - Sun. 8am - 8pm

Proudly serving the entire UK!

Give us a call
07526 985258
Send us an email
info@cleverbloom.co.uk
Technology catalog
AirHeatingCoolingHumidityWaterEnergyInsulation
Company
ProjectsBecome an installer
Social media
InstagramFacebooklinkedin
Documents
Privacy policyTerms and conditions
Location
Address: 3 Vickers house,  3 Hornchurch road UB10 0YG, London

© 2026 Clever Bloom — All rights reserved

Company registered in England and Wales / Company number: 14242566.