Family Passivhaus appliance · Waterborne UFH and radiators · 180L hot water · One cabinet
Waterborne heating in one cabinet
Integrated air-to-water heat pump for UFH or radiators · single appliance instead of separate ASHP + MVHR + cylinder
~9 kW heating output
Family Passivhaus territory · scales beyond air-only compact units · suitable for 140–200+ m² with proper UFH design
95% passive heat recovery
Counterflow heat exchanger plus active heat recovery via heat pump · effectively complete energy capture from extract air
PHI Passivhaus Institut certified
Cool temperate climates · Compact P platform certification · among the few hybrid units certified for Passivhaus worldwide
Single CTS602 control platform
One controller, one app, one BMS integration for ventilation + heating + cooling + DHW · eliminates multi-controller complexity
Reversible cooling cycle
Heat pump runs in reverse to cool supply air in summer · waste heat goes to top up hot water tank
Established UK market presence
16+ years of UK installs · A2Dominion Southall · widely recognised by SAP assessors and Passivhaus consultants
Modbus + Nilan app + service portal
Open Modbus TCP/IP and RS485 RTU · Nilan iOS / Android app · optional remote service portal for property managers
AIR9 combines three traditionally separate installations into one coordinated appliance: balanced MVHR with active heat recovery, an integrated air-to-water heat pump for waterborne heating to UFH or radiators, and 180-litre integrated domestic hot water. The interior unit sits in the plant room; the exterior heat pump module sits outside. One control platform runs everything — no separate ASHP controller, no separate cylinder thermostat.
The AIR9 outdoor unit extracts heat from outdoor air and delivers it as warm water to the home's heating circuit — typical heat pump COP behaviour. Variable-compressor design adapts heat output continuously to demand, rather than cycling on/off. Integrated circulation pump moves heated water between outdoor unit and indoor system. Suitable for low-temperature heating circuits (35–50°C flow) — UFH or sized radiators only, not high-temperature radiators.
Same Compact P architecture as the standard variant: passive counterflow heat exchanger captures up to 95% of extract air heat, then the integrated extract-air heat pump captures the residual 5–10%. Combined for effectively complete heat recovery from ventilation. This is independent from the AIR9 outdoor unit — even when the outdoor heat pump is off, the MVHR-side keeps recovering heat from the home.
The 180L hot water tank is heated by the MVHR-side extract air heat pump (same source as the standard Compact P) — using stable 20–22°C extract air rather than variable outdoor air. COP 3:1 average. Hot water production is decoupled from outdoor temperature, which means consistent performance year-round. Automatic weekly anti-legionella boost above 60°C via integrated immersion heater.
In summer, the MVHR-side heat pump runs in reverse to cool supply air by up to 10°C, while waste heat from the cooling cycle goes to top up the hot water tank — free hot water during cooling season. The AIR9 outdoor heat pump can also run in reverse for waterborne cooling to UFH (where UFH is specified for cooling). Combined cooling strategy across air and water for high-spec installs.
AIR9 indoor unit includes a 50-litre buffer tank for the central heating circuit (smooths heat pump cycling), pressurised expansion vessel, automatic safety valve, manometer, dirt filter, and 2 × 2 kW electric auxiliary heating elements (boost capacity for severe frost or rapid heat-up demand). All wet-side components factory-fitted — no separate hydraulic kit to assemble on site.
AIR9 ships with the CTS602 control system as standard — a single platform managing ventilation, waterborne heating, hot water, and cooling. One controller, one app, one BMS connection — eliminates multi-controller complexity that comes with separate ASHP + MVHR + cylinder installs. HMI Touch panel, integrated humidity sensor, automatic legionella protection, weekly schedule programming. Modbus TCP/IP and RS485 RTU for BMS integration. Nilan app for iOS and Android.
CTS602 HMI Touch panel
Standard Nilan control system with HMI Touch panel — graphical interface for ventilation steps, temperature setpoints, hot water schedule, and humidity control. Wall-mountable in living space or utility room. Multi-language support including English. Visual filter change reminder, alarm log, and energy consumption monitoring.
Nilan app · iOS / Android
Free Nilan mobile app for remote monitoring and control. Adjust ventilation step, change hot water setpoint, view alarm status, and monitor system performance — at home or away. Filter change reminders pushed to the app automatically when due. Single account supports multiple buildings — useful for landlords or property managers.
Nilan service portal
Optional remote service portal for ongoing monitoring by property managers, landlords, or maintenance teams. Diagnose issues remotely without site visit. Particularly useful for multi-unit residential developments — A2Dominion-style schemes where one operator manages dozens of Compact P installs across a development.
Modbus TCP/IP + RS485
Open Modbus communication standard — both TCP/IP (Ethernet) and RS485 RTU (serial) supported. Bidirectional — BMS can monitor every parameter and write settings, not just read status. Direct integration with Loxone, KNX (via gateway), Crestron, Niagara, or any Modbus-compatible BMS. Default protocol set to Modbus TCP/IP.
Intelligent humidity control
Built-in humidity sensor on the extract air circuit. CTS602 controller automatically increases ventilation when humidity rises (showers, cooking) and reduces ventilation in winter when indoor air is too dry. Adjustable threshold per room or whole-house. Reduces condensation risk and improves comfort without manual intervention. Standard on every Compact P.
CO₂ sensor (optional)
Optional Korea Digital SenseCube CO₂ sensor for demand-controlled ventilation. Increases airflow when occupancy raises CO₂ levels, drops to baseline when room is empty. NDIR dual-wavelength sensor, RS485 / 4–20mA / 0–10V outputs. Most useful for variable-occupancy spaces — guest rooms, home offices, multi-unit residential.
Heating circuit + AIR9 control
CTS602 manages the AIR9 outdoor heat pump, indoor circulation pump, buffer tank, and electric auxiliary heating elements as a coordinated system. Adjusts heat output continuously based on UFH or radiator demand. Compatible with weather compensation curves, room thermostats, and zone valves. Automatic legionella protection on the hot water tank as standard.
UFH zone + room thermostat integration
AIR9 supports per-room thermostats and zone valves on the UFH manifold. CTS602 reads room temperature feedback and modulates flow temperature accordingly. Weather compensation logic drops flow temperature in mild conditions to maximise heat pump efficiency. Cooker hood input, fireplace interlock, and external user-select inputs work the same way as standard Compact P.
AIR9 is a Passivhaus-class plant unit with both indoor and outdoor scope — best specified at the new-build design stage or as part of a deep retrofit / EnerPHit project. Typical sequence: design + sizing + UFH layout 4–6 weeks ahead; first-fix during construction; plant install in finished plant room plus outdoor unit positioning; commissioning and handover with full CTS602 setup, AIR9 heat pump start-up, and Nilan app pairing.
AIR9 sits in the upper tier of the Compact P range — for family Passivhaus and EnerPHit retrofits where waterborne UFH or radiators are required. Adjacent variants in the wider Compact P range either step down to air-only (Compact P standard) or scale up to ground-source (GEO) and multi-unit (XL) territory. Every variant shares the CTS602 control platform.
Compact P AIR9 — anchor configuration
Indoor unit (Compact P architecture) plus outdoor air-to-water heat pump module (~9 kW). Family Passivhaus territory — 140–200+ m². 275 m³/h max airflow, 95% passive heat recovery, 180L hot water tank, reversible cooling. Single-phase 230V indoors, dedicated heat pump circuit outdoors. CTS602 control. Variable-compressor outdoor unit. Buffer tank and 2 × 2 kW auxiliary heating included.
Step down — Compact P (air-only)
For projects where waterborne heating is not required, standard Compact P delivers air-only heating from the MVHR-side heat pump (no outdoor unit). The right pick for compact Passivhaus, apartments, and projects where airtightness and Passivhaus envelope make air-heating sufficient. No outdoor unit, single-cabinet install. Quote on request.
Step up — Compact P GEO 3 / 6 / 9
For projects with land for ground loops, GEO variants replace the air-to-water outdoor unit with a ground-source heat pump (3 kW, 6 kW, or 9 kW). Ground temperature is more stable than air — meaningfully higher seasonal efficiency than AIR9 at lower outdoor temperatures. Higher capital cost (groundworks), better long-term running costs. Quote on request.
Step up — Compact P XL
For larger family Passivhaus or multi-unit installations, Compact P XL scales airflow to 430 m³/h vs 275 m³/h on standard AIR9. Combines with AIR9 or GEO modules for waterborne heating. Same modular architecture, same heat recovery, same hot water tank. Right pick for 4+ bedroom Passivhaus, multi-occupancy schemes, or commercial offices with elevated fresh-air demand. Quote on request.
Polar variant for cold-climate sites
For exposed cold-climate installations (highland Scotland, Cumbria, sites above 200m elevation), AIR9 can be specified with a Polar pre-heater on the MVHR-side outdoor air intake. Protects the passive heat exchanger from icing during severe frost. Outdoor heat pump module continues operating at lower outdoor temperatures with appropriate defrost cycles. Specified at order based on site exposure.
Buffer tank · 50L standard
AIR9 indoor unit includes a 50-litre buffer tank in the central heating circuit by default — smooths heat pump cycling, reduces compressor wear, improves comfort during heat-up periods. Larger buffer tank options available for high-demand installs (multiple zones, large UFH areas). CleverBloom designs buffer sizing as part of the project brief.
UFH design + manifold integration
CleverBloom designs UFH layout alongside AIR9 — manifold positioning, zone valves, room thermostats, low-temperature pipework runs. Per-room control, weather compensation, and AIR9 flow-temperature optimisation engineered as a coordinated system. Suitable for ground-floor UFH only, or whole-house UFH including first-floor screed or bare-floor systems.
Filter upgrade options
Standard ISO Coarse / G4-equivalent filters fitted (75% pollen, dust, soot capture). Optional upgrade to F7 fine particulate filters (ePM1 70%) for households with allergy or asthma sensitivity, or installs in high-traffic urban areas (London, motorway proximity). Front-loading filter access — homeowner-replaceable in 5 minutes. CTS602 flags filter change automatically.
Compact P is designed for long service life — typically 15–20+ years of continuous operation. Filter changes and anode monitoring are routine; refrigerant circuit is sealed for life. Nilan manufacturer warranty + CleverBloom service plan together provide the support architecture for high-spec self-build, EnerPHit, and multi-unit residential clients.
Nilan manufacturer warranty
Standard Nilan manufacturer warranty applies — typically 2 years on full unit with extended coverage on heat pump and major components. Terms confirmed at order against current Nilan general conditions. Compact P installs covered through Nilan UK / Project Ziro Ltd, with their service portal supporting fault diagnosis and warranty claims directly.
Filter change · adjustable schedule
CTS602 filter timer adjustable from 30 to 180 days. Automatic alarm when filters due. Front-loading access via top front panel — homeowner-replaceable in 5 minutes, no tools. Standard ISO Coarse / G4 filters, optional F7 upgrade for allergy-sensitive households or high-pollution urban installs. Genuine Nilan replacement filters via Nilan UK service portal.
Electronically monitored anode
Sacrificial anode in the 180L hot water tank with electronic monitoring — CTS602 alarms when replacement is due (typically 5–10 years depending on water chemistry). Unlike unmonitored anodes that fail silently and damage the tank, the alarm prevents corrosion. Hard water areas may need more frequent replacement; soft water areas extend service life.
Automatic anti-legionella cycle
CTS602 boosts the hot water tank temperature to over 60°C automatically once weekly via the integrated immersion heater — kills any legionella that could grow during normal operation at 45–50°C. Required for Building Regulations Part G compliance. Boost cycle runs at off-peak hours to minimise electricity cost. No homeowner action needed.
Heat exchanger + outdoor unit service
MVHR-side counterflow heat exchanger requires no active maintenance — annual visual check during service visits. AIR9 outdoor unit benefits from annual service: visual check of refrigerant connections, condenser fin cleaning if visible debris, drainage check around unit. F-Gas registered engineer required for any refrigerant work. Refrigerant circuit hermetically sealed at factory.
CleverBloom Passivhaus service plan
For Compact P installs, CleverBloom offers an annual service plan covering: filter changes (parts and labour), anode status verification, control parameter review, ventilation airflow re-balance check, Nilan app account audit, and CTS602 firmware version review. Quoted per project based on access and SLA requirements. Multi-unit residential pricing available.
Heat pump unit only. Radiators, UFH, and emitters are on the heating page.
POA
Equipment only · 140–200+ m² · 9 kW air-to-water heat pump · 180L hot water · waterborne UFH · ex VAT
What's included
Variants & sizing alternatives
POA
Fully installed · equipment + design, first-fix, UFH & install
What's included
Variants & sizing alternatives
POA
Equipment only · 140–200+ m² · 9 kW air-to-water heat pump · 180L hot water · waterborne UFH · ex VAT
What's included
Variants & sizing alternatives
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur.
Block quote
Ordered list
Unordered list
Bold text
Emphasis
Superscript
Subscript

_11zon%20(1).webp)
Call us at 07526 985258
or leave your contact information below,
and we'll get back to you soon.
Join our certified installer network — leads, products, and technical support provided.
We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.
Working hours: Mon - Sun. 8am - 8pm
Proudly serving the entire UK!
© 2026 Clever Bloom — All rights reserved
Company registered in England and Wales / Company number: 14242566.