Waterborne UFH and radiators
Active heat recovery via heat pump
Reversible cooling cycle
CTS602 single control platform
Modbus TCP/IP + RS485 + Nilan app

Nilan Compact P AIR9

Family Passivhaus appliance · Waterborne UFH and radiators · 180L hot water · One cabinet

200+ m²
family Passivhaus territory
9kW
air-to-water heat pump
275m³/h
max airflow
95%
passive heat recovery
180L
hot water tank
PHI
Passivhaus certified
get a quote
Whats App instead
Why switch

Why this all-in-one heat pump

Waterborne heating in one cabinet

Integrated air-to-water heat pump for UFH or radiators · single appliance instead of separate ASHP + MVHR + cylinder

~9 kW heating output

Family Passivhaus territory · scales beyond air-only compact units · suitable for 140–200+ m² with proper UFH design

95% passive heat recovery

Counterflow heat exchanger plus active heat recovery via heat pump · effectively complete energy capture from extract air

PHI Passivhaus Institut certified

Cool temperate climates · Compact P platform certification · among the few hybrid units certified for Passivhaus worldwide

Single CTS602 control platform

One controller, one app, one BMS integration for ventilation + heating + cooling + DHW · eliminates multi-controller complexity

Reversible cooling cycle

Heat pump runs in reverse to cool supply air in summer · waste heat goes to top up hot water tank

Established UK market presence

16+ years of UK installs · A2Dominion Southall · widely recognised by SAP assessors and Passivhaus consultants

Modbus + Nilan app + service portal

Open Modbus TCP/IP and RS485 RTU · Nilan iOS / Android app · optional remote service portal for property managers

How it works
Specification
Control/App
Installation
components
Aftercare

Three integrated systems · one cabinet

AIR9 combines three traditionally separate installations into one coordinated appliance: balanced MVHR with active heat recovery, an integrated air-to-water heat pump for waterborne heating to UFH or radiators, and 180-litre integrated domestic hot water. The interior unit sits in the plant room; the exterior heat pump module sits outside. One control platform runs everything — no separate ASHP controller, no separate cylinder thermostat.

Air-to-water heat pump module

The AIR9 outdoor unit extracts heat from outdoor air and delivers it as warm water to the home's heating circuit — typical heat pump COP behaviour. Variable-compressor design adapts heat output continuously to demand, rather than cycling on/off. Integrated circulation pump moves heated water between outdoor unit and indoor system. Suitable for low-temperature heating circuits (35–50°C flow) — UFH or sized radiators only, not high-temperature radiators.

Two-stage MVHR heat recovery

Same Compact P architecture as the standard variant: passive counterflow heat exchanger captures up to 95% of extract air heat, then the integrated extract-air heat pump captures the residual 5–10%. Combined for effectively complete heat recovery from ventilation. This is independent from the AIR9 outdoor unit — even when the outdoor heat pump is off, the MVHR-side keeps recovering heat from the home.

Hot water from extract air

The 180L hot water tank is heated by the MVHR-side extract air heat pump (same source as the standard Compact P) — using stable 20–22°C extract air rather than variable outdoor air. COP 3:1 average. Hot water production is decoupled from outdoor temperature, which means consistent performance year-round. Automatic weekly anti-legionella boost above 60°C via integrated immersion heater.

Reversible cooling + free hot water

In summer, the MVHR-side heat pump runs in reverse to cool supply air by up to 10°C, while waste heat from the cooling cycle goes to top up the hot water tank — free hot water during cooling season. The AIR9 outdoor heat pump can also run in reverse for waterborne cooling to UFH (where UFH is specified for cooling). Combined cooling strategy across air and water for high-spec installs.

Buffer tank + safety hardware

AIR9 indoor unit includes a 50-litre buffer tank for the central heating circuit (smooths heat pump cycling), pressurised expansion vessel, automatic safety valve, manometer, dirt filter, and 2 × 2 kW electric auxiliary heating elements (boost capacity for severe frost or rapid heat-up demand). All wet-side components factory-fitted — no separate hydraulic kit to assemble on site.

Coverage 200+ m² 140–200+ m² family Passivhaus or EnerPHit retrofit. Suitable for new-build single-family homes, deep retrofits to Passivhaus standard, and projects where waterborne UFH or radiator heating is required. For projects under 140 m² with air-only heating, see Compact P standard.
Airflow 275 m³/h 50 to 275 m³/h variable. Reference flow for sound and efficiency data 265 m³/h at 250 Pa external pressure. EC fan motors with variable speed control. SEL/SFP values per Nilan planning data sheet.
Heat Recovery 95% Up to 95% temperature efficiency on the counterflow heat exchanger alone (passive). Active heat recovery via integrated heat pump captures the residual energy that the passive exchanger leaves behind — combining for effectively complete heat recovery from extract air. Per EN 308 / EN 13141-7.
Heating 9 kW Air-to-water heat pump (~9 kW heating output) for waterborne heating to UFH or low-temperature radiators. Variable-compressor design adapts output continuously to demand. Heat output per EN 14511 at A2/W35 confirmed at quote stage. Plus active heat recovery from MVHR side delivering supply-air conditioning.
Cooling −10°C Reversible cooling cycle — supply air cooled by up to 10°C below outdoor temperature. Waste heat from cooling cycle goes to top up the hot water tank — free hot water during cooling season. Note: not air conditioning. The 275 m³/h ventilation rate is sized for fresh air, not active room cooling.
Hot Water 180 L 180L integrated tank. Tapped volume 220L of 40°C water at 50°C tank setpoint. Heat pump uses extract air as the heat source — stable 20–22°C source year-round. Automatic weekly anti-legionella boost above 60°C. Electronically monitored sacrificial anode with replacement alarm. Built-in scalding protection at the tap.
Refrigerant Sealed Hermetically sealed cooling circuit. Modern Compact P models specified to current Nilan refrigerant standard — confirmed at order against latest UK F-gas regulations. Nilan publishes EU Ecodesign Directive compliant refrigerant data sheets per variant.
Electrical 230V · 1ph 230V single-phase, 50 Hz. EC fan motors. Hermetically-sealed compressor. 2 × 2 kW electric auxiliary heating elements (1 in tank, 1 in air supply for boost / frost protection). Standard mains supply, no 3-phase distribution required. RCD per UK Building Regulations.
Filtration F7 option Standard ISO Coarse / G4-equivalent filters (75% pollen, dust, soot capture). Optional F7 fine particulate filters (ePM1 70%) for allergy-sensitive households or high-pollution urban installs. Front-loading access. Filter timer 30–180 days, automatic CTS602 alarm.
Acoustic Insulated Sound data referenced at 275 m³/h and 100 Pa external per EN 9614-2 (surface) and EN 5136 (ducts). Sound power drops with falling air volume and reduced back-pressure. Sound-insulated panels in the cabinet keep plant-room emission low for installs adjacent to bedrooms.
Form Factor Split Indoor unit: vertical floor-standing cabinet (Compact P platform) housing MVHR core, hot water tank, buffer tank, and AIR9 hydraulic kit. Outdoor unit: air-to-water heat pump module on concrete pad or wall bracket — refrigerant lines run between. Combined plant footprint roughly equivalent to a typical boiler + cylinder install.
Certification PHI Passivhaus Institut PHI Certified Component for cool temperate climates — among only a handful of compact systems certified worldwide. EU Ecodesign Directive compliant. UK installations include A2Dominion Southall and other Passivhaus and Future Homes Standard schemes.

Control

AIR9 ships with the CTS602 control system as standard — a single platform managing ventilation, waterborne heating, hot water, and cooling. One controller, one app, one BMS connection — eliminates multi-controller complexity that comes with separate ASHP + MVHR + cylinder installs. HMI Touch panel, integrated humidity sensor, automatic legionella protection, weekly schedule programming. Modbus TCP/IP and RS485 RTU for BMS integration. Nilan app for iOS and Android.

CTS602 HMI Touch panel

Standard Nilan control system with HMI Touch panel — graphical interface for ventilation steps, temperature setpoints, hot water schedule, and humidity control. Wall-mountable in living space or utility room. Multi-language support including English. Visual filter change reminder, alarm log, and energy consumption monitoring.

Nilan app · iOS / Android

Free Nilan mobile app for remote monitoring and control. Adjust ventilation step, change hot water setpoint, view alarm status, and monitor system performance — at home or away. Filter change reminders pushed to the app automatically when due. Single account supports multiple buildings — useful for landlords or property managers.

Nilan service portal

Optional remote service portal for ongoing monitoring by property managers, landlords, or maintenance teams. Diagnose issues remotely without site visit. Particularly useful for multi-unit residential developments — A2Dominion-style schemes where one operator manages dozens of Compact P installs across a development.

Modbus TCP/IP + RS485

Open Modbus communication standard — both TCP/IP (Ethernet) and RS485 RTU (serial) supported. Bidirectional — BMS can monitor every parameter and write settings, not just read status. Direct integration with Loxone, KNX (via gateway), Crestron, Niagara, or any Modbus-compatible BMS. Default protocol set to Modbus TCP/IP.

Intelligent humidity control

Built-in humidity sensor on the extract air circuit. CTS602 controller automatically increases ventilation when humidity rises (showers, cooking) and reduces ventilation in winter when indoor air is too dry. Adjustable threshold per room or whole-house. Reduces condensation risk and improves comfort without manual intervention. Standard on every Compact P.

CO₂ sensor (optional)

Optional Korea Digital SenseCube CO₂ sensor for demand-controlled ventilation. Increases airflow when occupancy raises CO₂ levels, drops to baseline when room is empty. NDIR dual-wavelength sensor, RS485 / 4–20mA / 0–10V outputs. Most useful for variable-occupancy spaces — guest rooms, home offices, multi-unit residential.

Heating circuit + AIR9 control

CTS602 manages the AIR9 outdoor heat pump, indoor circulation pump, buffer tank, and electric auxiliary heating elements as a coordinated system. Adjusts heat output continuously based on UFH or radiator demand. Compatible with weather compensation curves, room thermostats, and zone valves. Automatic legionella protection on the hot water tank as standard.

UFH zone + room thermostat integration

AIR9 supports per-room thermostats and zone valves on the UFH manifold. CTS602 reads room temperature feedback and modulates flow temperature accordingly. Weather compensation logic drops flow temperature in mild conditions to maximise heat pump efficiency. Cooker hood input, fireplace interlock, and external user-select inputs work the same way as standard Compact P.

Installation

AIR9 is a Passivhaus-class plant unit with both indoor and outdoor scope — best specified at the new-build design stage or as part of a deep retrofit / EnerPHit project. Typical sequence: design + sizing + UFH layout 4–6 weeks ahead; first-fix during construction; plant install in finished plant room plus outdoor unit positioning; commissioning and handover with full CTS602 setup, AIR9 heat pump start-up, and Nilan app pairing.

01 Design + Nilan sizing 4–6 weeks before site Floor area, occupancy, hot water demand, and architectural layout reviewed. AIR9 specified vs alternatives (Compact P standard for air-only, GEO for ground source, XL for larger dwellings). UFH layout designed across all heated zones with manifold positioning. Outdoor unit location confirmed (acoustic, planning, refrigerant line length). Order placed via Nilan UK. Lead time confirmed at order.
02 First-fix + UFH + outdoor unit prep During construction Plant room positioned per design. Outdoor unit position prepared with concrete pad or wall bracket — accessible for service and refrigerant connections. UFH pipework laid in screed across heated zones, manifold positioned. Outdoor and exhaust ventilation ducts run. Single-phase 230V indoor circuit and dedicated heat pump electrical supply prepared with appropriate RCD. Cold water inlet, hot water flow/return, condensate drain.
03 Plant + outdoor unit install 1–2 days on site Compact P AIR9 indoor unit lifted into plant-room position. Outdoor heat pump module installed on prepared base. Refrigerant lines run between indoor and outdoor units (F-Gas registered engineer scope). UFH manifold connected to AIR9 flow and return. Buffer tank, pressurised expansion, safety hardware verified. Connections made to ductwork, DHW, cold water, condensate drain, and electrical supplies. HMI Touch panel mounted in living space.
04 Commissioning + handover 1 day on site CTS602 controller configured — ventilation steps, hot water schedule, UFH flow temperature curve, weather compensation. AIR9 heat pump self-test and start-up. Active heat recovery balanced and verified. UFH balanced across zones. Reversible cooling tested. Nilan app paired to homeowner's network. Modbus / Ethernet integration with BMS verified. Filter timer started. CleverBloom hands over Building Regulations Part F and Part L commissioning certificates, Nilan O&M documentation, and service plan options.

Configuration & sizing

AIR9 sits in the upper tier of the Compact P range — for family Passivhaus and EnerPHit retrofits where waterborne UFH or radiators are required. Adjacent variants in the wider Compact P range either step down to air-only (Compact P standard) or scale up to ground-source (GEO) and multi-unit (XL) territory. Every variant shares the CTS602 control platform.

Compact P AIR9 — anchor configuration

Indoor unit (Compact P architecture) plus outdoor air-to-water heat pump module (~9 kW). Family Passivhaus territory — 140–200+ m². 275 m³/h max airflow, 95% passive heat recovery, 180L hot water tank, reversible cooling. Single-phase 230V indoors, dedicated heat pump circuit outdoors. CTS602 control. Variable-compressor outdoor unit. Buffer tank and 2 × 2 kW auxiliary heating included.

Step down — Compact P (air-only)

For projects where waterborne heating is not required, standard Compact P delivers air-only heating from the MVHR-side heat pump (no outdoor unit). The right pick for compact Passivhaus, apartments, and projects where airtightness and Passivhaus envelope make air-heating sufficient. No outdoor unit, single-cabinet install. Quote on request.

Step up — Compact P GEO 3 / 6 / 9

For projects with land for ground loops, GEO variants replace the air-to-water outdoor unit with a ground-source heat pump (3 kW, 6 kW, or 9 kW). Ground temperature is more stable than air — meaningfully higher seasonal efficiency than AIR9 at lower outdoor temperatures. Higher capital cost (groundworks), better long-term running costs. Quote on request.

Step up — Compact P XL

For larger family Passivhaus or multi-unit installations, Compact P XL scales airflow to 430 m³/h vs 275 m³/h on standard AIR9. Combines with AIR9 or GEO modules for waterborne heating. Same modular architecture, same heat recovery, same hot water tank. Right pick for 4+ bedroom Passivhaus, multi-occupancy schemes, or commercial offices with elevated fresh-air demand. Quote on request.

Polar variant for cold-climate sites

For exposed cold-climate installations (highland Scotland, Cumbria, sites above 200m elevation), AIR9 can be specified with a Polar pre-heater on the MVHR-side outdoor air intake. Protects the passive heat exchanger from icing during severe frost. Outdoor heat pump module continues operating at lower outdoor temperatures with appropriate defrost cycles. Specified at order based on site exposure.

Buffer tank · 50L standard

AIR9 indoor unit includes a 50-litre buffer tank in the central heating circuit by default — smooths heat pump cycling, reduces compressor wear, improves comfort during heat-up periods. Larger buffer tank options available for high-demand installs (multiple zones, large UFH areas). CleverBloom designs buffer sizing as part of the project brief.

UFH design + manifold integration

CleverBloom designs UFH layout alongside AIR9 — manifold positioning, zone valves, room thermostats, low-temperature pipework runs. Per-room control, weather compensation, and AIR9 flow-temperature optimisation engineered as a coordinated system. Suitable for ground-floor UFH only, or whole-house UFH including first-floor screed or bare-floor systems.

Filter upgrade options

Standard ISO Coarse / G4-equivalent filters fitted (75% pollen, dust, soot capture). Optional upgrade to F7 fine particulate filters (ePM1 70%) for households with allergy or asthma sensitivity, or installs in high-traffic urban areas (London, motorway proximity). Front-loading filter access — homeowner-replaceable in 5 minutes. CTS602 flags filter change automatically.

Aftercare

Compact P is designed for long service life — typically 15–20+ years of continuous operation. Filter changes and anode monitoring are routine; refrigerant circuit is sealed for life. Nilan manufacturer warranty + CleverBloom service plan together provide the support architecture for high-spec self-build, EnerPHit, and multi-unit residential clients.

Nilan manufacturer warranty

Standard Nilan manufacturer warranty applies — typically 2 years on full unit with extended coverage on heat pump and major components. Terms confirmed at order against current Nilan general conditions. Compact P installs covered through Nilan UK / Project Ziro Ltd, with their service portal supporting fault diagnosis and warranty claims directly.

Filter change · adjustable schedule

CTS602 filter timer adjustable from 30 to 180 days. Automatic alarm when filters due. Front-loading access via top front panel — homeowner-replaceable in 5 minutes, no tools. Standard ISO Coarse / G4 filters, optional F7 upgrade for allergy-sensitive households or high-pollution urban installs. Genuine Nilan replacement filters via Nilan UK service portal.

Electronically monitored anode

Sacrificial anode in the 180L hot water tank with electronic monitoring — CTS602 alarms when replacement is due (typically 5–10 years depending on water chemistry). Unlike unmonitored anodes that fail silently and damage the tank, the alarm prevents corrosion. Hard water areas may need more frequent replacement; soft water areas extend service life.

Automatic anti-legionella cycle

CTS602 boosts the hot water tank temperature to over 60°C automatically once weekly via the integrated immersion heater — kills any legionella that could grow during normal operation at 45–50°C. Required for Building Regulations Part G compliance. Boost cycle runs at off-peak hours to minimise electricity cost. No homeowner action needed.

Heat exchanger + outdoor unit service

MVHR-side counterflow heat exchanger requires no active maintenance — annual visual check during service visits. AIR9 outdoor unit benefits from annual service: visual check of refrigerant connections, condenser fin cleaning if visible debris, drainage check around unit. F-Gas registered engineer required for any refrigerant work. Refrigerant circuit hermetically sealed at factory.

CleverBloom Passivhaus service plan

For Compact P installs, CleverBloom offers an annual service plan covering: filter changes (parts and labour), anode status verification, control parameter review, ventilation airflow re-balance check, Nilan app account audit, and CTS602 firmware version review. Quoted per project based on access and SLA requirements. Multi-unit residential pricing available.

Pricing

Transparent pricing.
Grant included.

Heat pump unit only. Radiators, UFH, and emitters are on the heating page.

No items found.
fully installed
supply only

POA

Equipment only · 140–200+ m² · 9 kW air-to-water heat pump · 180L hot water · waterborne UFH · ex VAT


What's included

Includes Nilan Compact P AIR9 indoor unit (vertical floor-standing cabinet with integrated MVHR, buffer tank, expansion vessel, safety hardware), AIR9 outdoor air-to-water heat pump module (~9 kW), 180L hot water tank with electronically monitored anode, CTS602 single-platform control with HMI Touch panel, EC fan motors, ISO Coarse / G4 filters, Modbus TCP/IP + RS485 RTU interface, Nilan app pairing, hermetically sealed refrigerant circuit, manufacturer warranty registration, and carriage from Denmark to UK site POA

Variants & sizing alternatives

Compact P (air-only, no outdoor unit, up to 140 m²) POA
Compact P GEO 3 / 6 / 9 (ground source heat pump) POA
Compact P XL (430 m³/h for larger dwellings) POA
Polar variant for cold-climate sites POA
Larger buffer tank for high-demand installs POA
F7 fine particulate filter upgrade POA
CO₂ sensor for demand-controlled ventilation POA
UFH manifold + zone valves + room thermostats POA
Equipment total ex VAT POA

POA

Fully installed · equipment + design, first-fix, UFH & install


What's included

Includes Nilan Compact P AIR9 indoor unit (vertical floor-standing cabinet with integrated MVHR, buffer tank, expansion vessel, safety hardware), AIR9 outdoor air-to-water heat pump module (~9 kW), 180L hot water tank with electronically monitored anode, CTS602 single-platform control with HMI Touch panel, EC fan motors, ISO Coarse / G4 filters, Modbus TCP/IP + RS485 RTU interface, Nilan app pairing, hermetically sealed refrigerant circuit, manufacturer warranty registration, and carriage from Denmark to UK site POA
Design + first-fix + UFH + install POA

Variants & sizing alternatives

Compact P (air-only, no outdoor unit, up to 140 m²) POA
Compact P GEO 3 / 6 / 9 (ground source heat pump) POA
Compact P XL (430 m³/h for larger dwellings) POA
Polar variant for cold-climate sites POA
Larger buffer tank for high-demand installs POA
F7 fine particulate filter upgrade POA
CO₂ sensor for demand-controlled ventilation POA
UFH manifold + zone valves + room thermostats POA
Project total POA

POA

Equipment only · 140–200+ m² · 9 kW air-to-water heat pump · 180L hot water · waterborne UFH · ex VAT


What's included

Includes Nilan Compact P AIR9 indoor unit (vertical floor-standing cabinet with integrated MVHR, buffer tank, expansion vessel, safety hardware), AIR9 outdoor air-to-water heat pump module (~9 kW), 180L hot water tank with electronically monitored anode, CTS602 single-platform control with HMI Touch panel, EC fan motors, ISO Coarse / G4 filters, Modbus TCP/IP + RS485 RTU interface, Nilan app pairing, hermetically sealed refrigerant circuit, manufacturer warranty registration, and carriage from Denmark to UK site POA

Variants & sizing alternatives

Compact P (air-only, no outdoor unit, up to 140 m²) POA
Compact P GEO 3 / 6 / 9 (ground source heat pump) POA
Compact P XL (430 m³/h for larger dwellings) POA
Polar variant for cold-climate sites POA
Larger buffer tank for high-demand installs POA
F7 fine particulate filter upgrade POA
CO₂ sensor for demand-controlled ventilation POA
UFH manifold + zone valves + room thermostats POA
Equipment total ex VAT POA
Equipment
£11,200
Installation & commissioning
£4,300
Fully installed
£15,500
After £7,500 BUS grant 0% VAT until March 2027
£8,000
get a quote
Whats App instead
No items found.

Technical specifications

Coverage 200+ m² 140–200+ m² family Passivhaus or EnerPHit retrofit. Suitable for new-build single-family homes, deep retrofits to Passivhaus standard, and projects where waterborne UFH or radiator heating is required. For projects under 140 m² with air-only heating, see Compact P standard.
Airflow 275 m³/h 50 to 275 m³/h variable. Reference flow for sound and efficiency data 265 m³/h at 250 Pa external pressure. EC fan motors with variable speed control. SEL/SFP values per Nilan planning data sheet.
Heat Recovery 95% Up to 95% temperature efficiency on the counterflow heat exchanger alone (passive). Active heat recovery via integrated heat pump captures the residual energy that the passive exchanger leaves behind — combining for effectively complete heat recovery from extract air. Per EN 308 / EN 13141-7.
Heating 9 kW Air-to-water heat pump (~9 kW heating output) for waterborne heating to UFH or low-temperature radiators. Variable-compressor design adapts output continuously to demand. Heat output per EN 14511 at A2/W35 confirmed at quote stage. Plus active heat recovery from MVHR side delivering supply-air conditioning.
Cooling −10°C Reversible cooling cycle — supply air cooled by up to 10°C below outdoor temperature. Waste heat from cooling cycle goes to top up the hot water tank — free hot water during cooling season. Note: not air conditioning. The 275 m³/h ventilation rate is sized for fresh air, not active room cooling.
Hot Water 180 L 180L integrated tank. Tapped volume 220L of 40°C water at 50°C tank setpoint. Heat pump uses extract air as the heat source — stable 20–22°C source year-round. Automatic weekly anti-legionella boost above 60°C. Electronically monitored sacrificial anode with replacement alarm. Built-in scalding protection at the tap.
Refrigerant Sealed Hermetically sealed cooling circuit. Modern Compact P models specified to current Nilan refrigerant standard — confirmed at order against latest UK F-gas regulations. Nilan publishes EU Ecodesign Directive compliant refrigerant data sheets per variant.
Electrical 230V · 1ph 230V single-phase, 50 Hz. EC fan motors. Hermetically-sealed compressor. 2 × 2 kW electric auxiliary heating elements (1 in tank, 1 in air supply for boost / frost protection). Standard mains supply, no 3-phase distribution required. RCD per UK Building Regulations.
Filtration F7 option Standard ISO Coarse / G4-equivalent filters (75% pollen, dust, soot capture). Optional F7 fine particulate filters (ePM1 70%) for allergy-sensitive households or high-pollution urban installs. Front-loading access. Filter timer 30–180 days, automatic CTS602 alarm.
Acoustic Insulated Sound data referenced at 275 m³/h and 100 Pa external per EN 9614-2 (surface) and EN 5136 (ducts). Sound power drops with falling air volume and reduced back-pressure. Sound-insulated panels in the cabinet keep plant-room emission low for installs adjacent to bedrooms.
Form Factor Split Indoor unit: vertical floor-standing cabinet (Compact P platform) housing MVHR core, hot water tank, buffer tank, and AIR9 hydraulic kit. Outdoor unit: air-to-water heat pump module on concrete pad or wall bracket — refrigerant lines run between. Combined plant footprint roughly equivalent to a typical boiler + cylinder install.
Certification PHI Passivhaus Institut PHI Certified Component for cool temperate climates — among only a handful of compact systems certified worldwide. EU Ecodesign Directive compliant. UK installations include A2Dominion Southall and other Passivhaus and Future Homes Standard schemes.

Works with

No items found.

Installed by CleverBloom

No items found.

About products

arrow

Heading 1

Heading 2

Heading 3

Heading 4

Heading 5
Heading 6

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur.

Block quote

Ordered list

  1. Item 1
  2. Item 2
  3. Item 3

Unordered list

  • Item A
  • Item B
  • Item C

Text link

Bold text

Emphasis

Superscript

Subscript

line

Request a Service

Call us at 07526 985258

or leave your contact information below,
and we'll get back to you soon.

Thank you! Your message has been sent. We’ll get back to you soon!
Oops! Something went wrong. Please try again or check your details and submit again.

Ready for a better building?

Join our certified installer network — leads, products, and technical support provided.

Whats App instead
Clever Bloom - Smart Home and MVHR Ventilation Installation UK

We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.

Working hours: Mon - Sun. 8am - 8pm

Proudly serving the entire UK!

Give us a call
07526 985258
Send us an email
info@cleverbloom.co.uk
Technology catalog
AirHeatingCoolingHumidityWaterEnergyInsulation
Company
ProjectsBecome an installer
Social media
InstagramFacebooklinkedin
Documents
Privacy policyTerms and conditions
Location
Address: 3 Vickers house,  3 Hornchurch road UB10 0YG, London

© 2026 Clever Bloom — All rights reserved

Company registered in England and Wales / Company number: 14242566.