Ventilation + heating + cooling + 220L hot water · Single appliance · No outdoor unit required
R1234yf refrigerant
GWP < 1 · future-proof under UK F-Gas · vs R410A on most competitors (GWP 2,088)
Patented dual-circuit heat pump
Two independent circuits · air + DHW operate in parallel · unique to Pichler
PHI Passivhaus Institut certified
Cool temperate climates · 0.29 W/(m³h) electrical efficiency · 83% heat recovery (PHI standard)
No outdoor unit required
Outdoor and exhaust air via façade elements · no condenser to plan around
4-in-1 compact appliance
MVHR + heating + cooling + DHW · 0.75 m² footprint · single contractor scope
Smart Grid + PV Ready
Eco-mode for solar self-consumption · pairs cleanly with PV + battery
Pichler app + Modbus / KNX
iOS / Android app · remote service · KNX gateway optional · Modbus RTU standard
Single-phase 230V · 16A
Standard mains · no 3-phase distribution · simpler new-build electrical design
PKOM4A unites four functions in a single appliance: balanced ventilation with heat recovery (MVHR), supply-air heating via heat pump, supply-air cooling via reversible refrigerant circuit, and 220-litre domestic hot water heating via a dedicated separate heat pump. One contract, one appliance, one footprint of 0.75 m² — replaces a separate MVHR + ASHP + hot water cylinder.
Two independent heat pump circuits operate in parallel: one conditions the supply air (heating or cooling), the other heats the 220L hot water tank. Both run R1234yf refrigerant (GWP < 1) with frequency-controlled rotating piston compressors. Pichler's patent allows simultaneous cooling and DHW heating — the waste heat from cooling the supply air is recovered to heat the hot water tank. Genuine free hot water in summer.
Standard variant uses a plastic counterflow heat exchanger — 92% temperature change recovery (EN 16573), 83% PHI heat recovery efficiency. Optional enthalpy exchanger upgrade recovers humidity from extract air in winter — important in dry climates and for occupant comfort. Specified at order via the article number suffix (.S = standard, .F = enthalpy).
The supply-air heat pump circuit is reversible — same hardware delivers heating in winter and cooling in summer. Cooling power up to 1,365 W via heat recovery, or 1,950 W maximum at A35 conditions. The 4-way switching valve handles seasonal changeover automatically. Real summer comfort in well-insulated Passivhaus or EnerPhit buildings without specifying a separate cooling system.
A second compressor circuit dedicated to the 220L hot water tank. Heats DHW to 55°C from heat pump alone, or 65°C with the integrated 1,500 W electric heating element for legionella protection. Energy efficiency class A (80.3% per EU 812/2013), 1,274 kWh annual electricity for water heating with the L (Large) load profile. Impressed-current titanium anode protects the tank lining indefinitely without sacrificial replacement.
Summer bypass flap routes incoming outdoor air around the heat exchanger when outdoor air is cooler than indoor. Free cooling at night — pulls cool outdoor air directly into the living space without pre-warming via the recovery exchanger. Combined with the active heat pump cooling, gives PKOM4A two cooling strategies: passive bypass (free) for mild summer nights, active heat pump (efficient) for hot days.
PKOM4A ships with a TFT touch display, integrated room temperature sensor, web server, and LAN interface as standard. Pichler app for iOS/Android plus Pichler Connect remote service. Modbus RTU serial interface for building automation. Optional KNX gateway, CO₂ + humidity sensors, and Smart Grid / PV Ready integration for solar self-consumption.
TFT touch display
Built-in colour TFT touch display — controller dimensions 110 × 84 × 25 mm, mounted in living space. Integrated room temperature sensor. Operates summer/winter changeover, holiday function, individually adjustable air volumes, time-of-day and day-of-week scheduling, energy balancing visualisation. Mounted via standard telephone-installation wiring up to 100m run.
Pichler app · iOS / Android
Free Pichler smartphone app for remote monitoring and control. Adjust airflow, switch operating modes, view system status, monitor energy consumption — at home or away. Connects via the integrated web server and LAN interface. No additional cloud subscription required.
Pichler Connect remote service
Optional remote diagnostics — Pichler customer service automatically receives malfunction alerts and can intervene remotely with minimal disruption. Useful for self-builders without a regular HVAC engineer relationship. Activated by removing a sticker from the LAN socket and connecting an internet cable. GDPR-compliant data handling.
Modbus RTU integration
Standard Modbus RTU interface for connection to building automation systems. Direct integration with KNX (via gateway), Loxone, Crestron, or any Modbus-compatible BMS. Supports the full PKOM4A parameter set — operating mode, airflow, temperature setpoints, energy data — readable and writable via BMS.
KNX gateway · article 08KNXGAC
Optional Modbus/KNX gateway for full KNX bus integration — DIN-rail mounted, 18 × 100 × 60 mm. Acts as Modbus master and standard KNX TP-1 device. Bidirectional control via ETS Config Tool (DCA). Critical for high-end self-build / Passivhaus projects with KNX-based whole-house automation. KNX bus power supply only (~8 mA), no separate PSU needed.
Smart Grid Ready · PV Ready
Eco-Mode for solar self-consumption — when PV system signals surplus generation, PKOM4A increases hot water heating and pre-heats supply air to maximise on-site solar use. Integrates with Pichler PSOL+ energy management for full system optimisation across PV, battery, hybrid inverter, and PKOM4A. Real benefit for Passivhaus + PV homes targeting net zero.
CO₂ + humidity sensors (optional)
Demand-controlled ventilation via optional sensors. CO₂ sensor (07RCO248330) measures 0–2000 ppm, increases airflow when occupancy rises. Humidity sensor (07RHF49360) wall-mount or duct-mount (07KTRHF49337) modulates airflow against indoor RH. Reference signal 0–10V. Useful for variable-occupancy spaces — guest rooms, home offices, multi-family buildings.
Solar + heating circuit integration
Optional heating coil in the hot water tank (.W variant) accepts external heat input from solar thermal, biomass, or secondary heat pump. Optional heating circuit module enables connection to underfloor heating zones with separate room-temperature sensors. Pichler app shows energy contribution from each source — useful for verifying real-world solar payback.
PKOM4A is a Passivhaus-class plant unit at 240 kg with substantial first-fix and electrical scope. Best specified at the new-build design stage or as part of a deep retrofit / EnerPHit project. Typical project sequence: design + sizing 4–6 weeks ahead; first-fix during construction; plant install in finished plant room; commissioning and handover via manufacturer-licensed engineer.
PKOM4A Classic is the right pick for Passivhaus or EnerPHit homes of 80–130 m² with hot water demand for a family of 4–5. Smaller-home and ventilation-only variants exist within the same architecture. All share the dual-circuit heat pump platform, R1234yf refrigerant, TFT touch control, Pichler app, and PHI certification.
PKOM4A Classic — anchor configuration
80–130 m² Passivhaus living area. 130–250 m³/h heating airflow. 1,786 W heat output (with HR) at A2/A35. 220L hot water tank, family of 4–5. R1234yf refrigerant. Counterflow heat exchanger standard, enthalpy upgrade optional. Powder-coated steel casing 741 × 2003 × 734 mm. 240 kg. Single-phase 230V/16A.
PKOM4AK Classic — smaller home variant
Up to 80 m² Passivhaus living area. 80–150 m³/h heating airflow. 1,077 W heat output (with HR). Same 220L hot water tank — slightly lower DHW heat output (750 W vs 1,400 W). Same dimensions and casing. Right pick for compact Passivhaus, two-bed apartments, retrofit EnerPHit. Quote on request.
Standard vs enthalpy heat exchanger
Standard plastic counterflow heat exchanger (.S suffix) — 92% temperature change recovery, suits typical UK climate. Optional enthalpy exchanger (.F suffix) recovers humidity from extract air in winter — beneficial for very dry indoor climates or households with low moisture generation. Specified at order.
Heating coil in hot water tank
Optional heating coil (.W suffix) integrated into the 220L hot water tank — accepts external heat input from solar thermal collectors, biomass boiler, or secondary heat pump. Tank volume reduces from 220L to 212L when coil specified. Most useful for solar-thermal-equipped homes and biomass-heated rural Passivhaus.
Trend variants — without DHW
PKOM4A Trend (130 m², 250 m³/h) and PKOM4AK Trend (80 m², 150 m³/h) — same compact heat pump combi architecture without the 220L hot water tank. Right pick for projects where DHW is provided separately by solar-thermal or another heat pump. 140 kg, 1,334 mm height (vs 2,003 mm Classic). 750 W or 580 W max power. Quote on request.
Left- vs right-handed casing
PKOM4A Classic and AK Classic are available in left-handed (article suffix L) or right-handed (suffix R) configuration — refers to the side of the unit on which duct connections, hot water connections, and electrical entry are positioned. Specified at order based on plant-room layout. No price difference between handedness.
Optional duct heating battery 1.2 kW
For very cold UK winters (extended sub-zero periods), an optional 1,200 W duct heating battery (article 08CV16121VICIAL) supplements PKOM4A heat output. Activated automatically by the controller when the heat pump alone cannot meet supply-air temperature setpoint. Ø160 mm duct connection, 375 mm installation length. Includes duct temperature sensor (40LG041920).
Optional air humidification unit
LBE 250 ARO/ALO patented air humidification unit (article 08LBE250ARO right / 08LBE250ALO left) — installed downstream of PKOM4A. Natural-evaporation principle with UVC disinfection and integrated reverse osmosis water treatment. 4.5–11.5 g/m³ humidity boost, max 2.5 L/h evaporation. For very dry indoor climates or households with sensitive occupants.
PKOM4A is designed for long service life in residential Passivhaus settings — typically 15–20+ years of continuous operation. Filter changes and impressed-current anode are routine; refrigerant circuit and heat pumps are sealed for life under normal use. Manufacturer warranty + CleverBloom service plan together provide the support architecture for high-spec self-build and EnerPHit clients.
Manufacturer warranty
Standard Pichler manufacturer warranty applies — terms confirmed at order against current Pichler general conditions. Typical Austrian-manufacturer warranty covers 2 years on full unit, with extended coverage available on heat pump components subject to commissioning by manufacturer-licensed engineer (which is required for warranty validity on any PKOM4A install).
Filter change · F7 + M5
F7 outdoor air filter (article 40LG050290, glass fibre, ISO ePM1 55%) and M5 extract air filter (article 40LG050280, synthetic, ISO ePM10 75%). Both replaced typically every 6 months — TFT controller flags filter change automatically based on operating hours. Genuine spare filters from Pichler authorised channels only — third-party filters may compromise heat exchanger life.
TFT filter change command
"Bitte Luftfilter wechseln!" prompt appears on the TFT touch controller when filters are due. Field-replaceable by homeowner via the filter inspection flap — no tools, 5-minute job. Reset the timer via the controller after replacement. If filters not changed when prompted, the system continues operating but power consumption increases and heat recovery efficiency degrades.
Impressed-current anode
PKOM4A Classic uses a titanium impressed-current anode in the 220L hot water tank — applies a controlled electrical potential to protect the steel tank lining against corrosion. Unlike sacrificial magnesium anodes, the impressed-current anode does NOT require periodic replacement under normal water chemistry. Verified via the dedicated anode circuit board — fault status reported via TFT and Pichler app.
Refrigerant inspection
R1234yf refrigerant circuits are sealed for life. UK F-gas regulations apply — inspection by F-Gas registered engineer required only at end-of-life or after refrigerant work. PKOM4A's 1,000g fill is well below the 5,000g threshold for annual leak checks, making routine compliance simple. Refrigerant choice (R1234yf, GWP < 1) future-proofs the install against UK F-gas tightening.
CleverBloom Passivhaus service plan
For PKOM4A installs, CleverBloom offers an annual service plan covering: filter changes (parts and labour), coil and condensate drain inspection, anode status verification, control parameter review, ventilation airflow re-balance check, Pichler app account audit, and TFT firmware version review. Quoted per project based on access and SLA requirements.
Heat pump unit only. Radiators, UFH, and emitters are on the heating page.
£14,000
Equipment only · 80–130 m² Passivhaus · 220L hot water · R1234yf refrigerant · ex VAT
What's included
Variants & sizing alternatives
POA
Fully installed · equipment + design, first-fix & install
What's included
Variants & sizing alternatives
£14,000
Equipment only · 80–130 m² Passivhaus · 220L hot water · R1234yf refrigerant · ex VAT
What's included
Variants & sizing alternatives
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur.
Block quote
Ordered list
Unordered list
Bold text
Emphasis
Superscript
Subscript

_11zon%20(1).webp)
Call us at 07526 985258
or leave your contact information below,
and we'll get back to you soon.
Join our certified installer network — leads, products, and technical support provided.
We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.
Working hours: Mon - Sun. 8am - 8pm
Proudly serving the entire UK!
© 2026 Clever Bloom — All rights reserved
Company registered in England and Wales / Company number: 14242566.