  • Pichler PKOM4A Classic
R1234yf refrigerant · GWP < 1
Patented dual-circuit heat pump
PHI Passivhaus Institut certified
Smart Grid Ready · PV Ready

Pichler PKOM4A Classic

Ventilation + heating + cooling + 220L hot water · Single appliance · No outdoor unit required

130m²
Passivhaus living area
250m³/h
max airflow heating mode
92%
heat recovery (EN 16573)
220L
hot water tank
A class
water heating efficiency
37dB(A)
housing emission at 1m
get a quote
Whats App instead
Why switch

Why this compact service unit

R1234yf refrigerant

GWP < 1 · future-proof under UK F-Gas · vs R410A on most competitors (GWP 2,088)

Patented dual-circuit heat pump

Two independent circuits · air + DHW operate in parallel · unique to Pichler

PHI Passivhaus Institut certified

Cool temperate climates · 0.29 W/(m³h) electrical efficiency · 83% heat recovery (PHI standard)

No outdoor unit required

Outdoor and exhaust air via façade elements · no condenser to plan around

4-in-1 compact appliance

MVHR + heating + cooling + DHW · 0.75 m² footprint · single contractor scope

Smart Grid + PV Ready

Eco-mode for solar self-consumption · pairs cleanly with PV + battery

Pichler app + Modbus / KNX

iOS / Android app · remote service · KNX gateway optional · Modbus RTU standard

Single-phase 230V · 16A

Standard mains · no 3-phase distribution · simpler new-build electrical design

How it works
Specification
Control/App
Installation
components
Aftercare

4-in-1 functional cycle

PKOM4A unites four functions in a single appliance: balanced ventilation with heat recovery (MVHR), supply-air heating via heat pump, supply-air cooling via reversible refrigerant circuit, and 220-litre domestic hot water heating via a dedicated separate heat pump. One contract, one appliance, one footprint of 0.75 m² — replaces a separate MVHR + ASHP + hot water cylinder.

Patented dual-circuit heat pumps

Two independent heat pump circuits operate in parallel: one conditions the supply air (heating or cooling), the other heats the 220L hot water tank. Both run R1234yf refrigerant (GWP < 1) with frequency-controlled rotating piston compressors. Pichler's patent allows simultaneous cooling and DHW heating — the waste heat from cooling the supply air is recovered to heat the hot water tank. Genuine free hot water in summer.

Counterflow heat exchanger (or enthalpy)

Standard variant uses a plastic counterflow heat exchanger — 92% temperature change recovery (EN 16573), 83% PHI heat recovery efficiency. Optional enthalpy exchanger upgrade recovers humidity from extract air in winter — important in dry climates and for occupant comfort. Specified at order via the article number suffix (.S = standard, .F = enthalpy).

Reversible cooling circuit

The supply-air heat pump circuit is reversible — same hardware delivers heating in winter and cooling in summer. Cooling power up to 1,365 W via heat recovery, or 1,950 W maximum at A35 conditions. The 4-way switching valve handles seasonal changeover automatically. Real summer comfort in well-insulated Passivhaus or EnerPhit buildings without specifying a separate cooling system.

DHW heat pump cycle

A second compressor circuit dedicated to the 220L hot water tank. Heats DHW to 55°C from heat pump alone, or 65°C with the integrated 1,500 W electric heating element for legionella protection. Energy efficiency class A (80.3% per EU 812/2013), 1,274 kWh annual electricity for water heating with the L (Large) load profile. Impressed-current titanium anode protects the tank lining indefinitely without sacrificial replacement.

Bypass flap · free cooling

Summer bypass flap routes incoming outdoor air around the heat exchanger when outdoor air is cooler than indoor. Free cooling at night — pulls cool outdoor air directly into the living space without pre-warming via the recovery exchanger. Combined with the active heat pump cooling, gives PKOM4A two cooling strategies: passive bypass (free) for mild summer nights, active heat pump (efficient) for hot days.

Coverage 130 m² 80–130 m² Passivhaus living area. Hot water for a family of 4–5. PKOM4AK Classic covers up to 80 m² (smaller home variant). Trend variants (no DHW) available for projects with separate hot water source.
Airflow 250 m³/h 85–250 m³/h variable in ventilation mode. 130–250 m³/h in heating mode. PHI reference flow 175 m³/h. 4 ventilation stages selectable. External pressure capacity > 200 Pa at maximum flow.
Heat Recovery 92% 92% temperature change recovery (EN 16573, standard counterflow exchanger). 83% PHI heat recovery efficiency. Optional enthalpy exchanger recovers humidity in winter. 1.4% external / 1.9% internal leakage.
Heat Output 1,786 W 1,786 W (with HR) / 860 W (without HR) heat pump output at A2/A35, Vref 175 m³/h. Maximum 2,362 W with heat recovery. COP 5.91 with HR / 3.32 without HR. Operating outdoor temperature −15°C to +40°C.
Cooling Power 1,207 W 1,207 W with HR / 655 W without HR cooling output at A35/A27 and Vref. Maximum 1,950 W with HR / 1,365 W without HR. EER 3.29. Bypass flap for free cooling on cool summer nights — passive option supplements active heat-pump cooling.
Hot Water 220 L 220L tank (212L with optional heating coil .W variant). 1,400 W heat pump output to DHW. Up to 55°C from heat pump alone, 65°C with electric backup (1,500 W). Energy efficiency class A, 80.3% efficiency. 1,274 kWh annual electricity (Load profile L). Impressed-current titanium anode.
Refrigerant R1234yf R1234yf — GWP < 1, future-proof under UK F-gas regulations. 1,000 g fill per circuit (well below 5,000 g annual leak-check threshold). Two independent circuits — one for ventilation/space conditioning (HC), one for domestic hot water (DHW). Both circuits hermetically sealed.
Electrical 230V · 16A 230V single-phase, 50 Hz. 2,800 W maximum power consumption. 12.8 A max current. C16A line fuse. Type B current-impulse-sensitive RCD required (heat pump compatibility). Dedicated circuit recommended.
Filtration F7 + M5 Outdoor air filter F7 — ISO ePM1 55% (article 40LG050290, glass fibre). Extract air filter M5 — ISO ePM10 75% (article 40LG050280, synthetic). Pollen, fine dust, PM2.5, mould spores, smog particles. TFT controller flags filter change automatically.
Acoustic 37 dB(A) 47.1 dB(A) housing emission (LWA total at 250 m³/h, 100 Pa, heat pump active). 37.3 dB(A) at 1m sound pressure level. Recommended in sound-insulated plant room separated from living areas for full Passivhaus comfort.
Dimensions 240 kg 741 × 2003 × 734 mm (W × H × D). 240 kg. Powder-coated sheet steel casing. Floor-standing plant unit. Footprint < 0.75 m². Trend variants are 1,334 mm tall (no hot water tank). Left or right hand orientation specified at order.
Certification PHI Passivhaus Institut PHI certified for cool temperate climates. EU Ecodesign Directive compliant per EU 812/813-2013. Energy efficiency class A for water heating. Built It 2018 Best Renewable Heating Solution. Green Home Award 2021 Highly Recommended.

Control

PKOM4A ships with a TFT touch display, integrated room temperature sensor, web server, and LAN interface as standard. Pichler app for iOS/Android plus Pichler Connect remote service. Modbus RTU serial interface for building automation. Optional KNX gateway, CO₂ + humidity sensors, and Smart Grid / PV Ready integration for solar self-consumption.

TFT touch display

Built-in colour TFT touch display — controller dimensions 110 × 84 × 25 mm, mounted in living space. Integrated room temperature sensor. Operates summer/winter changeover, holiday function, individually adjustable air volumes, time-of-day and day-of-week scheduling, energy balancing visualisation. Mounted via standard telephone-installation wiring up to 100m run.

Pichler app · iOS / Android

Free Pichler smartphone app for remote monitoring and control. Adjust airflow, switch operating modes, view system status, monitor energy consumption — at home or away. Connects via the integrated web server and LAN interface. No additional cloud subscription required.

Pichler Connect remote service

Optional remote diagnostics — Pichler customer service automatically receives malfunction alerts and can intervene remotely with minimal disruption. Useful for self-builders without a regular HVAC engineer relationship. Activated by removing a sticker from the LAN socket and connecting an internet cable. GDPR-compliant data handling.

Modbus RTU integration

Standard Modbus RTU interface for connection to building automation systems. Direct integration with KNX (via gateway), Loxone, Crestron, or any Modbus-compatible BMS. Supports the full PKOM4A parameter set — operating mode, airflow, temperature setpoints, energy data — readable and writable via BMS.

KNX gateway · article 08KNXGAC

Optional Modbus/KNX gateway for full KNX bus integration — DIN-rail mounted, 18 × 100 × 60 mm. Acts as Modbus master and standard KNX TP-1 device. Bidirectional control via ETS Config Tool (DCA). Critical for high-end self-build / Passivhaus projects with KNX-based whole-house automation. KNX bus power supply only (~8 mA), no separate PSU needed.

Smart Grid Ready · PV Ready

Eco-Mode for solar self-consumption — when PV system signals surplus generation, PKOM4A increases hot water heating and pre-heats supply air to maximise on-site solar use. Integrates with Pichler PSOL+ energy management for full system optimisation across PV, battery, hybrid inverter, and PKOM4A. Real benefit for Passivhaus + PV homes targeting net zero.

CO₂ + humidity sensors (optional)

Demand-controlled ventilation via optional sensors. CO₂ sensor (07RCO248330) measures 0–2000 ppm, increases airflow when occupancy rises. Humidity sensor (07RHF49360) wall-mount or duct-mount (07KTRHF49337) modulates airflow against indoor RH. Reference signal 0–10V. Useful for variable-occupancy spaces — guest rooms, home offices, multi-family buildings.

Solar + heating circuit integration

Optional heating coil in the hot water tank (.W variant) accepts external heat input from solar thermal, biomass, or secondary heat pump. Optional heating circuit module enables connection to underfloor heating zones with separate room-temperature sensors. Pichler app shows energy contribution from each source — useful for verifying real-world solar payback.

Installation

PKOM4A is a Passivhaus-class plant unit at 240 kg with substantial first-fix and electrical scope. Best specified at the new-build design stage or as part of a deep retrofit / EnerPHit project. Typical project sequence: design + sizing 4–6 weeks ahead; first-fix during construction; plant install in finished plant room; commissioning and handover via manufacturer-licensed engineer.

01 Design + Pichler sizing 4–6 weeks before site Living area, occupancy, hot water demand, and external air supply route reviewed. PKOM4A or AK Classic specified based on m² and DHW load. Counterflow or enthalpy exchanger chosen. Standard or heating-coil tank chosen. Left/right hand confirmed against plant-room layout. Façade air supply elements designed to integrate with architectural drawings. Order placed via authorised UK supply channel. 6–8 week lead time from Austria.
02 First-fix + façade ducts During construction Plant room positioned per design. Façade outdoor and exhaust air elements installed (Ø160 or Ø200 mm) — built into the building envelope before insulation and external finish. Supply and extract ductwork run to all habitable rooms. Single-phase 230V/16A circuit run to plant room with Type B current-impulse-sensitive RCD. DHW flow/return pipework, cold water inlet, condensate drain. KNX bus run if specified.
03 Plant install (240 kg) 1 day on site PKOM4A delivered on a pallet — 240 kg requires planning for delivery access and floor loading. Lifted into final plant-room position via mechanical aid (pallet truck, sack truck, or two-person lift). Connections made to ductwork (Ø160 or Ø200), DHW inlet/outlet, cold water, condensate drain, and electrical supply. TFT touch display mounted in living space and connected via telephone-installation wiring (max 100m).
04 Commissioning + handover 1 day on site Initial power-up by CleverBloom. Manufacturer-licensed commissioning engineer attends site to load licensed Pichler software, configure operating parameters, run heat pump self-test, balance the ventilation circuit, verify DHW heat pump operation, and certify the install. Pichler app paired to homeowner's network. Pichler Connect remote service activated if specified. CleverBloom hands over O&M documentation, warranty registration, filter change schedule, and service plan options.

Configuration & sizing

PKOM4A Classic is the right pick for Passivhaus or EnerPHit homes of 80–130 m² with hot water demand for a family of 4–5. Smaller-home and ventilation-only variants exist within the same architecture. All share the dual-circuit heat pump platform, R1234yf refrigerant, TFT touch control, Pichler app, and PHI certification.

PKOM4A Classic — anchor configuration

80–130 m² Passivhaus living area. 130–250 m³/h heating airflow. 1,786 W heat output (with HR) at A2/A35. 220L hot water tank, family of 4–5. R1234yf refrigerant. Counterflow heat exchanger standard, enthalpy upgrade optional. Powder-coated steel casing 741 × 2003 × 734 mm. 240 kg. Single-phase 230V/16A.

PKOM4AK Classic — smaller home variant

Up to 80 m² Passivhaus living area. 80–150 m³/h heating airflow. 1,077 W heat output (with HR). Same 220L hot water tank — slightly lower DHW heat output (750 W vs 1,400 W). Same dimensions and casing. Right pick for compact Passivhaus, two-bed apartments, retrofit EnerPHit. Quote on request.

Standard vs enthalpy heat exchanger

Standard plastic counterflow heat exchanger (.S suffix) — 92% temperature change recovery, suits typical UK climate. Optional enthalpy exchanger (.F suffix) recovers humidity from extract air in winter — beneficial for very dry indoor climates or households with low moisture generation. Specified at order.

Heating coil in hot water tank

Optional heating coil (.W suffix) integrated into the 220L hot water tank — accepts external heat input from solar thermal collectors, biomass boiler, or secondary heat pump. Tank volume reduces from 220L to 212L when coil specified. Most useful for solar-thermal-equipped homes and biomass-heated rural Passivhaus.

Trend variants — without DHW

PKOM4A Trend (130 m², 250 m³/h) and PKOM4AK Trend (80 m², 150 m³/h) — same compact heat pump combi architecture without the 220L hot water tank. Right pick for projects where DHW is provided separately by solar-thermal or another heat pump. 140 kg, 1,334 mm height (vs 2,003 mm Classic). 750 W or 580 W max power. Quote on request.

Left- vs right-handed casing

PKOM4A Classic and AK Classic are available in left-handed (article suffix L) or right-handed (suffix R) configuration — refers to the side of the unit on which duct connections, hot water connections, and electrical entry are positioned. Specified at order based on plant-room layout. No price difference between handedness.

Optional duct heating battery 1.2 kW

For very cold UK winters (extended sub-zero periods), an optional 1,200 W duct heating battery (article 08CV16121VICIAL) supplements PKOM4A heat output. Activated automatically by the controller when the heat pump alone cannot meet supply-air temperature setpoint. Ø160 mm duct connection, 375 mm installation length. Includes duct temperature sensor (40LG041920).

Optional air humidification unit

LBE 250 ARO/ALO patented air humidification unit (article 08LBE250ARO right / 08LBE250ALO left) — installed downstream of PKOM4A. Natural-evaporation principle with UVC disinfection and integrated reverse osmosis water treatment. 4.5–11.5 g/m³ humidity boost, max 2.5 L/h evaporation. For very dry indoor climates or households with sensitive occupants.

Aftercare

PKOM4A is designed for long service life in residential Passivhaus settings — typically 15–20+ years of continuous operation. Filter changes and impressed-current anode are routine; refrigerant circuit and heat pumps are sealed for life under normal use. Manufacturer warranty + CleverBloom service plan together provide the support architecture for high-spec self-build and EnerPHit clients.

Manufacturer warranty

Standard Pichler manufacturer warranty applies — terms confirmed at order against current Pichler general conditions. Typical Austrian-manufacturer warranty covers 2 years on full unit, with extended coverage available on heat pump components subject to commissioning by manufacturer-licensed engineer (which is required for warranty validity on any PKOM4A install).

Filter change · F7 + M5

F7 outdoor air filter (article 40LG050290, glass fibre, ISO ePM1 55%) and M5 extract air filter (article 40LG050280, synthetic, ISO ePM10 75%). Both replaced typically every 6 months — TFT controller flags filter change automatically based on operating hours. Genuine spare filters from Pichler authorised channels only — third-party filters may compromise heat exchanger life.

TFT filter change command

"Bitte Luftfilter wechseln!" prompt appears on the TFT touch controller when filters are due. Field-replaceable by homeowner via the filter inspection flap — no tools, 5-minute job. Reset the timer via the controller after replacement. If filters not changed when prompted, the system continues operating but power consumption increases and heat recovery efficiency degrades.

Impressed-current anode

PKOM4A Classic uses a titanium impressed-current anode in the 220L hot water tank — applies a controlled electrical potential to protect the steel tank lining against corrosion. Unlike sacrificial magnesium anodes, the impressed-current anode does NOT require periodic replacement under normal water chemistry. Verified via the dedicated anode circuit board — fault status reported via TFT and Pichler app.

Refrigerant inspection

R1234yf refrigerant circuits are sealed for life. UK F-gas regulations apply — inspection by F-Gas registered engineer required only at end-of-life or after refrigerant work. PKOM4A's 1,000g fill is well below the 5,000g threshold for annual leak checks, making routine compliance simple. Refrigerant choice (R1234yf, GWP < 1) future-proofs the install against UK F-gas tightening.

CleverBloom Passivhaus service plan

For PKOM4A installs, CleverBloom offers an annual service plan covering: filter changes (parts and labour), coil and condensate drain inspection, anode status verification, control parameter review, ventilation airflow re-balance check, Pichler app account audit, and TFT firmware version review. Quoted per project based on access and SLA requirements.

Pricing

Transparent pricing.
Grant included.

Heat pump unit only. Radiators, UFH, and emitters are on the heating page.

No items found.
fully installed
supply only

£14,000

Equipment only · 80–130 m² Passivhaus · 220L hot water · R1234yf refrigerant · ex VAT


What's included

Includes Pichler PKOM4A Classic unit (powder-coated steel casing, white), standard counterflow heat exchanger (.S variant), TFT touch display with integrated room sensor, F7 outdoor + M5 extract filters, web server + LAN interface, Pichler app pairing, Modbus RTU interface, Smart Grid / PV Ready integration, manufacturer warranty registration, manufacturer-licensed commissioning, and carriage from Austria to UK site £14,000

Variants & sizing alternatives

PKOM4AK Classic (up to 80 m², smaller home) POA
PKOM4A Trend (no DHW, 130 m²) POA
PKOM4AK Trend (no DHW, 80 m²) POA
Enthalpy exchanger upgrade (.F suffix) POA
Heating coil in HW tank (.W suffix) POA
KNX gateway (08KNXGAC) POA
Duct heating battery 1.2 kW (08CV16121VICIAL) POA
Air humidification unit LBE 250 (08LBE250ARO/ALO) POA
Equipment total ex VAT £14,000

POA

Fully installed · equipment + design, first-fix & install


What's included

Includes Pichler PKOM4A Classic unit (powder-coated steel casing, white), standard counterflow heat exchanger (.S variant), TFT touch display with integrated room sensor, F7 outdoor + M5 extract filters, web server + LAN interface, Pichler app pairing, Modbus RTU interface, Smart Grid / PV Ready integration, manufacturer warranty registration, manufacturer-licensed commissioning, and carriage from Austria to UK site £14,000
Design + first-fix + install POA

Variants & sizing alternatives

PKOM4AK Classic (up to 80 m², smaller home) POA
PKOM4A Trend (no DHW, 130 m²) POA
PKOM4AK Trend (no DHW, 80 m²) POA
Enthalpy exchanger upgrade (.F suffix) POA
Heating coil in HW tank (.W suffix) POA
KNX gateway (08KNXGAC) POA
Duct heating battery 1.2 kW (08CV16121VICIAL) POA
Air humidification unit LBE 250 (08LBE250ARO/ALO) POA
Project total POA

£14,000

Equipment only · 80–130 m² Passivhaus · 220L hot water · R1234yf refrigerant · ex VAT


What's included

Includes Pichler PKOM4A Classic unit (powder-coated steel casing, white), standard counterflow heat exchanger (.S variant), TFT touch display with integrated room sensor, F7 outdoor + M5 extract filters, web server + LAN interface, Pichler app pairing, Modbus RTU interface, Smart Grid / PV Ready integration, manufacturer warranty registration, manufacturer-licensed commissioning, and carriage from Austria to UK site £14,000

Variants & sizing alternatives

PKOM4AK Classic (up to 80 m², smaller home) POA
PKOM4A Trend (no DHW, 130 m²) POA
PKOM4AK Trend (no DHW, 80 m²) POA
Enthalpy exchanger upgrade (.F suffix) POA
Heating coil in HW tank (.W suffix) POA
KNX gateway (08KNXGAC) POA
Duct heating battery 1.2 kW (08CV16121VICIAL) POA
Air humidification unit LBE 250 (08LBE250ARO/ALO) POA
Equipment total ex VAT £14,000
Equipment
£11,200
Installation & commissioning
£4,300
Fully installed
£15,500
After £7,500 BUS grant 0% VAT until March 2027
£8,000
get a quote
Whats App instead
No items found.

Technical specifications

Coverage 130 m² 80–130 m² Passivhaus living area. Hot water for a family of 4–5. PKOM4AK Classic covers up to 80 m² (smaller home variant). Trend variants (no DHW) available for projects with separate hot water source.
Airflow 250 m³/h 85–250 m³/h variable in ventilation mode. 130–250 m³/h in heating mode. PHI reference flow 175 m³/h. 4 ventilation stages selectable. External pressure capacity > 200 Pa at maximum flow.
Heat Recovery 92% 92% temperature change recovery (EN 16573, standard counterflow exchanger). 83% PHI heat recovery efficiency. Optional enthalpy exchanger recovers humidity in winter. 1.4% external / 1.9% internal leakage.
Heat Output 1,786 W 1,786 W (with HR) / 860 W (without HR) heat pump output at A2/A35, Vref 175 m³/h. Maximum 2,362 W with heat recovery. COP 5.91 with HR / 3.32 without HR. Operating outdoor temperature −15°C to +40°C.
Cooling Power 1,207 W 1,207 W with HR / 655 W without HR cooling output at A35/A27 and Vref. Maximum 1,950 W with HR / 1,365 W without HR. EER 3.29. Bypass flap for free cooling on cool summer nights — passive option supplements active heat-pump cooling.
Hot Water 220 L 220L tank (212L with optional heating coil .W variant). 1,400 W heat pump output to DHW. Up to 55°C from heat pump alone, 65°C with electric backup (1,500 W). Energy efficiency class A, 80.3% efficiency. 1,274 kWh annual electricity (Load profile L). Impressed-current titanium anode.
Refrigerant R1234yf R1234yf — GWP < 1, future-proof under UK F-gas regulations. 1,000 g fill per circuit (well below 5,000 g annual leak-check threshold). Two independent circuits — one for ventilation/space conditioning (HC), one for domestic hot water (DHW). Both circuits hermetically sealed.
Electrical 230V · 16A 230V single-phase, 50 Hz. 2,800 W maximum power consumption. 12.8 A max current. C16A line fuse. Type B current-impulse-sensitive RCD required (heat pump compatibility). Dedicated circuit recommended.
Filtration F7 + M5 Outdoor air filter F7 — ISO ePM1 55% (article 40LG050290, glass fibre). Extract air filter M5 — ISO ePM10 75% (article 40LG050280, synthetic). Pollen, fine dust, PM2.5, mould spores, smog particles. TFT controller flags filter change automatically.
Acoustic 37 dB(A) 47.1 dB(A) housing emission (LWA total at 250 m³/h, 100 Pa, heat pump active). 37.3 dB(A) at 1m sound pressure level. Recommended in sound-insulated plant room separated from living areas for full Passivhaus comfort.
Dimensions 240 kg 741 × 2003 × 734 mm (W × H × D). 240 kg. Powder-coated sheet steel casing. Floor-standing plant unit. Footprint < 0.75 m². Trend variants are 1,334 mm tall (no hot water tank). Left or right hand orientation specified at order.
Certification PHI Passivhaus Institut PHI certified for cool temperate climates. EU Ecodesign Directive compliant per EU 812/813-2013. Energy efficiency class A for water heating. Built It 2018 Best Renewable Heating Solution. Green Home Award 2021 Highly Recommended.

Works with

No items found.

Installed by CleverBloom

No items found.

About products

arrow

Heading 1

Heading 2

Heading 3

Heading 4

Heading 5
Heading 6

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur.

Block quote

Ordered list

  1. Item 1
  2. Item 2
  3. Item 3

Unordered list

  • Item A
  • Item B
  • Item C

Text link

Bold text

Emphasis

Superscript

Subscript

line

Request a Service

Call us at 07526 985258

or leave your contact information below,
and we'll get back to you soon.

Thank you! Your message has been sent. We’ll get back to you soon!
Oops! Something went wrong. Please try again or check your details and submit again.

Ready for a better building?

Join our certified installer network — leads, products, and technical support provided.

Whats App instead
Clever Bloom - Smart Home and MVHR Ventilation Installation UK

We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.

Working hours: Mon - Sun. 8am - 8pm

Proudly serving the entire UK!

Give us a call
07526 985258
Send us an email
info@cleverbloom.co.uk
Technology catalog
AirHeatingCoolingHumidityWaterEnergyInsulation
Company
ProjectsBecome an installer
Social media
InstagramFacebooklinkedin
Documents
Privacy policyTerms and conditions
Location
Address: 3 Vickers house,  3 Hornchurch road UB10 0YG, London

© 2026 Clever Bloom — All rights reserved

Company registered in England and Wales / Company number: 14242566.