Side-connected ducts (loft/ceiling friendly)
Rotary heat exchanger with moisture transfer
EC RadiCal fans

Systemair SAVE VSR 300

Whole-house MVHR · Side-connected for lofts & ceiling installs · Up to 240 m² · Rotary heat & moisture transfer

78%
heat recovery
270m³/h
certified airflow
240m²
coverage
0.35Wh/m³
specific power
1670W
integrated reheater
2yr
warranty
get a quote
Whats App instead
Why switch

Side-connected for loft & ceiling installs

Horizontal-orientation unit · ducts on the side, not the top

78% heat recovery — Passivhaus certified

Component ID 1085VS03 · independently tested

Rotary exchanger with moisture transfer

Recovers heat and humidity · prevents winter condensation

Filtered air to every room

F7 supply (EPM1 50%) · G4 extract (ISO Coarse 60%)

Up to 240 m² whole-house coverage

3-4 bed family homes, small commercial, classrooms

Built-in 1670 W reheater for cold winters

No frost-protection failures, comfortable supply at −10°C

Inspection hatches both sides

Easier service access in tight loft spaces · L or R hand

SAVE Touch + SAVE Connect app

Touchscreen mounts on wall or unit · WiFi remote · Modbus RS-485

How it works
Specification
Control/App
Installation
components
Aftercare

Side-connected horizontal mount

All four duct connections are on the side of the unit (not the top), and the unit lies horizontally rather than standing vertically. Designed for ceiling voids, lofts, attics, suspended ceilings, or floor-mounted basement plant — anywhere a wall-mounted vertical unit (like the VTR) won't fit. L or R hand variants suit different room layouts.

Whole-house balanced flow

A single VSR 300 unit serves homes up to 240 m². Filtered fresh air is supplied to habitable rooms (bedrooms, living rooms, study); stale air is extracted from wet rooms (kitchens, bathrooms, utility). Two EC RadiCal fans run continuously to maintain balanced pressure across the whole home.

Rotary heat exchanger

A slowly-rotating aluminium wheel sits between the supply and extract air streams. Each side absorbs heat from the warm air it passes, then releases it into the cooler air on the next rotation. This design also transfers some humidity back into the supply — preventing winter dryness without an enthalpy core.

F7 + G4 filter set

Standard configuration: F7 (ISO ePM1 50%) on the supply side, G4 (ISO Coarse 60%) on the extract side per the Passivhaus certificate. F7 catches pollen, fine dust, smog particles. The control panel's filter timer flags replacement, typically every 6–12 months depending on outdoor air quality.

Demand-driven control

A built-in humidity sensor in the extract air enables demand control as standard — the unit ramps fan speed when shower steam or kitchen activity drives RH up. Optional CO₂ sensor adds occupancy-driven control. Manual override always available via the SAVE Touch panel.

Built-in 1670 W reheater

An integrated electric reheater downstream of the rotor maintains a comfortable supply air temperature even at outdoor temperatures of −10°C. The reheater is thermostatically controlled — only draws power when needed. Required for Passivhaus comfort criterion (supply air ≥16.5°C at −10°C outdoor).

Airflow 270 m³/h Passivhaus certified airflow range 100–270 m³/h. Wider envelope than the wall-mounted VTR 300/B sister (140–230 m³/h). Demand-driven control modulates between minimum, low, normal, and high modes.
Heat Recovery 78% Variable-speed rotary heat exchanger with moisture transfer. Passivhaus-certified 78% heat recovery efficiency at 100–270 m³/h. Moisture transfer back to supply air prevents winter dryness.
Sound Level 50.7 dB(A) Sound power 50.7 dB(A) at the device, 270 m³/h (per PHI test). Exceeds the 35 dB(A) Passivhaus comfort target — the unit must be installed acoustically separated from living areas, and silencers are required on supply and extract ducts.
Energy Class Passivhaus Passivhaus certified component (ID 1085vs03). Eurovent certified. ErP compliant. Suitable for Building Regulations Part F, EnerPHit retrofits, and small commercial scopes (offices, classrooms).
Power Use 0.35 Wh/m³ Specific electric power 0.35 Wh/m³ Passivhaus certified — slightly better than the wall-mounted VTR 300/B sister (0.38 Wh/m³). Standby power 8.2 W. Two EC RadiCal fans on 230 V single-phase mains. Internal/external leakage 2.92% / 0.76%.
Frost Protection 1670 W Rotary heat exchanger handles low outdoor temperatures without external pre-heater. Integrated 1670 W electric supply heater maintains supply air ≥16.5°C at outdoor temperatures down to −10°C — meets Passivhaus comfort criterion.
Construction Side connect Double-skinned, fully insulated cabinet. Designed to lie horizontally with side-connected ducts. Inspection hatches on both sides for service access. Heat exchanger removable from side. Left or right hand variants — confirm at order.

Control

The VSR 300 ships with a SAVE Touch colour touchscreen panel that connects to the unit via the connection board. The panel can be mounted on the unit itself or remoted to a wall position — useful when the plant unit lives in the loft. Plus optional SAVE CONNECT WiFi/cloud, Modbus RS-485, and demand-control sensors.

SAVE Touch panel (wall or unit)

Full-colour touchscreen, user-friendly interface. Connects via the side connection board. Mount on the unit if it's accessible, or wire to a convenient wall position elsewhere in the home — ideal when the plant lives in the loft. Multiple panels can be daisy-chained for larger installs.

SAVE CONNECT (WiFi)

Optional WiFi accessory module for remote access via the SAVE Connect mobile app (iOS and Android) or the homesolutions.systemair.com web portal. Local or remote control, no LAN cabling required, links to Amazon Alexa and Google Home for voice control.

Modbus RS-485

Standard on every unit. Direct integration with home automation and BMS systems via Modbus protocol — useful for commercial installs (offices, classrooms) where ventilation needs to integrate with heating and lighting control.

Built-in humidity sensor

Standard — fitted in the extract air chamber from factory. Demand control is enabled out of the box: the unit ramps fan speed when extract RH rises (shower, cooking, drying laundry). No optional sensor needed for this.

Optional CO₂ sensor

Add-on CO₂ sensor for occupancy-driven control. Useful for home offices, classrooms, and bedrooms where humidity-only control isn't enough. Wires directly into the connection board on the side of the unit.

Week schedule

Built into the SAVE Touch controller — set up to two airflow time periods per day across each day of the week. Useful for homes with predictable occupancy patterns (away during working hours, busier in evenings).

Boost / refresh mode

Timed boost at high speed for clearing odours after cooking, fast air change after gatherings, or post-shower humidity. Returns to scheduled airflow automatically. Triggered via touchscreen, app, or external switch.

Automatic summer mode

When indoor temperature exceeds the set threshold and outdoor air is cooler, the unit automatically switches to summer operation — cooling recovery without active heat exchange. Returns to winter operation as conditions change.

Installation

Centralised whole-house MVHR is a significantly bigger install than a wall unit — typically 3–5 days on site, plus a design phase. The VSR 300 is the right pick when the plant location is a loft, ceiling void, or horizontal floor mount — where a vertical wall-mounted VTR wouldn't fit.

01 Design 2–3 weeks before site Room-by-room ventilation calculation per Building Regulations Part F and Passivhaus methodology. Plant location confirmed (loft, ceiling void, basement). L or R hand orientation chosen to suit ductwork. Supply and extract terminals marked on architect drawings. Acoustic silencer positions specified.
02 First-fix ductwork 1–2 days on site Ductwork installed before plasterboard / floor finishes. Side-connected ducts run horizontally from the unit. Supply ducts to habitable rooms, extract from kitchens / bathrooms / utility. Insulated duct in unconditioned voids (cold lofts especially). Acoustic silencers fitted on supply and extract — required per the Passivhaus certificate.
03 Plant install 1 day on site VSR 300 lifted into position (loft floor, ceiling void or basement plinth). Heat exchanger removable for the install to make the unit lighter. Four side-connected duct unions made. Mains 230 V supply. SAVE Touch panel routed from the unit to a wall position if the plant isn't accessible.
04 Commission Half day Run the SAVE Touch start-up wizard. Set airflow per design (l/s, m³/h or %), calibrate to filter type. Measure and verify with a Testo 405i anemometer at every supply and extract terminal per BESA DW/143. Hand over operating manual, app credentials, filter change schedule.

Components

Centralised whole-house MVHR. The VSR 300 plant unit sits horizontally in a service location (loft, ceiling void, suspended ceiling, basement floor) with four side-connected duct runs to fresh-air intake, exhaust outlet, supply manifold, and extract manifold.

VSR 300 plant unit

Double-skinned panels, fully insulated cabinet. Designed to lie horizontally — sits on a loft floor, in a ceiling void, or on a basement plinth. Compact footprint suits tight roof spaces. Left or right hand variants — confirm at order.

Rotary heat exchanger

Variable-speed rotating exchanger with moisture transfer. Removable for cleaning every 3 years (or sooner if airflow performance drops). Drive belt is the only consumable hardware in the rotor mechanism.

EC RadiCal fans

Two RadiCal impeller fans with EC (electronically commutated) motors. Modern brushless DC technology — quiet operation, low specific fan power (0.35 Wh/m³ Passivhaus certified), 50% less energy than equivalent AC motors. Lifetime-lubricated bearings, maintenance-free.

Four side-connected duct spigots

All four ducts (intake, exhaust, supply, extract) connect on the side of the unit — the defining VSR architecture. Allows ductwork to run horizontally from the unit into a flat ceiling void or loft, without the vertical clearance that top-connected units (like the VTR series) need.

F7 + G4 filter set

F7 (ISO ePM1 50%) supply filter and G4 (ISO Coarse 60%) extract filter per the Passivhaus certificate. Tool-free replacement. Higher-grade alternatives available for urban or pollen-heavy environments.

Integrated 1670 W reheater

Electric reheater downstream of the rotor — maintains supply air ≥16.5°C even at outdoor temperatures of -10°C (Passivhaus comfort criterion). Thermostatically controlled, only draws power when needed.

Inspection hatches both sides

Service access from either side of the unit — a meaningful advantage when the plant lives in a tight loft or basement plinth. Means the rotor, fans, and filters can be reached without dismantling adjacent ductwork.

SAVE CONNECT cloud module

Optional WiFi accessory for remote control via the SAVE Connect mobile app or web portal. Plugs into the connection board on the side of the unit. Required for app control, not needed for local SAVE Touch panel operation.

Aftercare

The VSR 300 is engineered for long-term low-touch operation. Filters change in under five minutes; the rotor is removable for periodic cleaning; the ductwork itself has no moving parts. Inspection hatches on both sides simplify service access in tight loft spaces.

2-year manufacturer warranty

Systemair provides a 2-year manufacturer warranty on the unit as standard. Built to Eurovent certification and ErP compliance with global service network. Mature platform — Systemair has been making rotary MVHR since 1974.

Filter change every 6–12 months

F7 supply and G4 extract filters, accessed via the side inspection hatches. Tool-free replacement. The SAVE Touch panel flags when change is due (default 12 months, adjustable 3–15 months). Filter sets typically £25–40 from UK distributors.

Removable rotary exchanger

The heat exchanger lifts out from the side for cleaning every 3 years (or sooner if airflow performance drops). Wash in hot soapy water (no ammonia detergents). Both-sided access makes servicing in loft spaces significantly easier than top-only-access units.

Drive belt — replaceable

A rubber drive belt rotates the heat exchanger via the rotor motor. The SAVE Touch controller flags an alarm if the belt slips or breaks. Replacement is straightforward — Systemair supplies the belt as a service spare. Plan for one belt change in a 10-year service life.

Ductwork — no scheduled maintenance

Once correctly installed and balanced, modern smooth-bore plastic ductwork runs maintenance-free. Periodic visual inspection of intake/exhaust grilles for leaf or debris accumulation is the only routine task.

Optional CleverBloom service plan

For homeowners who don't want to climb into the loft annually, CleverBloom offers a yearly visit covering filter change, rotor inspection, flow rate verification with anemometer, and any sensor recalibration. Specify at handover.

Pricing

Transparent pricing.
Grant included.

Heat pump unit only. Radiators, UFH, and emitters are on the heating page.

No items found.
fully installed
supply only

£2,670

Equipment only · no installation


What's included

Systemair SAVE VSR 300 unit (L or R variant) £2,670
Includes rotary heat exchanger with moisture transfer, EC RadiCal fans, SAVE Touch panel, 1670 W reheater, F7 + G4 filter set, both-side inspection hatches —

Optional add-ons

Acoustic silencers (REQUIRED for residential install — see spec) quote
SAVE CONNECT WiFi cloud module quote
Additional SAVE Touch panel (multi-position) quote
CO₂ sensor add-on quote
F7 + G4 replacement filter set £25–40
Ductwork system (per design) quote
Equipment total £2,670

£5,170

Fully installed (excl. ductwork & silencers) · equipment + design, install & commissioning


What's included

Systemair SAVE VSR 300 unit (L or R variant) £2,670
Includes rotary heat exchanger with moisture transfer, EC RadiCal fans, SAVE Touch panel, 1670 W reheater, F7 + G4 filter set, both-side inspection hatches —
Design, install & commissioning £2,500

Optional add-ons

Acoustic silencers (REQUIRED for residential install — see spec) quote
SAVE CONNECT WiFi cloud module quote
Additional SAVE Touch panel (multi-position) quote
CO₂ sensor add-on quote
F7 + G4 replacement filter set £25–40
Ductwork system (per design) quote
Fully installed total (excl. ductwork & silencers) £5,170

£2,670

Equipment only · no installation


What's included

Systemair SAVE VSR 300 unit (L or R variant) £2,670
Includes rotary heat exchanger with moisture transfer, EC RadiCal fans, SAVE Touch panel, 1670 W reheater, F7 + G4 filter set, both-side inspection hatches —

Optional add-ons

Acoustic silencers (REQUIRED for residential install — see spec) quote
SAVE CONNECT WiFi cloud module quote
Additional SAVE Touch panel (multi-position) quote
CO₂ sensor add-on quote
F7 + G4 replacement filter set £25–40
Ductwork system (per design) quote
Equipment total £2,670
Equipment
£11,200
Installation & commissioning
£4,300
Fully installed
£15,500
After £7,500 BUS grant 0% VAT until March 2027
£8,000
get a quote
Whats App instead
No items found.

Technical specifications

Airflow 270 m³/h Passivhaus certified airflow range 100–270 m³/h. Wider envelope than the wall-mounted VTR 300/B sister (140–230 m³/h). Demand-driven control modulates between minimum, low, normal, and high modes.
Heat Recovery 78% Variable-speed rotary heat exchanger with moisture transfer. Passivhaus-certified 78% heat recovery efficiency at 100–270 m³/h. Moisture transfer back to supply air prevents winter dryness.
Sound Level 50.7 dB(A) Sound power 50.7 dB(A) at the device, 270 m³/h (per PHI test). Exceeds the 35 dB(A) Passivhaus comfort target — the unit must be installed acoustically separated from living areas, and silencers are required on supply and extract ducts.
Energy Class Passivhaus Passivhaus certified component (ID 1085vs03). Eurovent certified. ErP compliant. Suitable for Building Regulations Part F, EnerPHit retrofits, and small commercial scopes (offices, classrooms).
Power Use 0.35 Wh/m³ Specific electric power 0.35 Wh/m³ Passivhaus certified — slightly better than the wall-mounted VTR 300/B sister (0.38 Wh/m³). Standby power 8.2 W. Two EC RadiCal fans on 230 V single-phase mains. Internal/external leakage 2.92% / 0.76%.
Frost Protection 1670 W Rotary heat exchanger handles low outdoor temperatures without external pre-heater. Integrated 1670 W electric supply heater maintains supply air ≥16.5°C at outdoor temperatures down to −10°C — meets Passivhaus comfort criterion.
Construction Side connect Double-skinned, fully insulated cabinet. Designed to lie horizontally with side-connected ducts. Inspection hatches on both sides for service access. Heat exchanger removable from side. Left or right hand variants — confirm at order.

Works with

No items found.

Installed by CleverBloom

No items found.

About products

arrow

Heading 1

Heading 2

Heading 3

Heading 4

Heading 5
Heading 6

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur.

Block quote

Ordered list

  1. Item 1
  2. Item 2
  3. Item 3

Unordered list

  • Item A
  • Item B
  • Item C

Text link

Bold text

Emphasis

Superscript

Subscript

line

Request a Service

Call us at 07526 985258

or leave your contact information below,
and we'll get back to you soon.

Thank you! Your message has been sent. We’ll get back to you soon!
Oops! Something went wrong. Please try again or check your details and submit again.

Ready for a better building?

Join our certified installer network — leads, products, and technical support provided.

Whats App instead
Clever Bloom - Smart Home and MVHR Ventilation Installation UK

We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.

Working hours: Mon - Sun. 8am - 8pm

Proudly serving the entire UK!

Give us a call
07526 985258
Send us an email
info@cleverbloom.co.uk
Technology catalog
AirHeatingCoolingHumidityWaterEnergyInsulation
Company
ProjectsBecome an installer
Social media
InstagramFacebooklinkedin
Documents
Privacy policyTerms and conditions
Location
Address: 3 Vickers house,  3 Hornchurch road UB10 0YG, London

© 2026 Clever Bloom — All rights reserved

Company registered in England and Wales / Company number: 14242566.