We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.
Working hours: Mon - Sun. 8am - 8pm
Proudly serving the entire UK!
Company
Whole-house MVHR · Family homes & small commercial · Up to 240 m² · Rotary heat & moisture transfer
Rotary exchanger with moisture transfer
Recovers heat AND humidity · prevents winter condensation
78% heat recovery — Passivhaus certified
Component ID 1090vs03 · independently tested
Mature Swedish engineering since 1974
Eurovent certified · ErP compliant · global service network
Filtered air to every room
F7 supply (ePM1 60%) · M5 or G3 extract
Up to 240 m² whole-house coverage
3-4 bed family homes, small commercial, classrooms
Built-in 1670 W reheater for cold winters
No frost-protection failures, comfortable supply at −10°C
Cooker hood bypass connection
Kitchen extract diverts heat exchanger — no grease build-up
SAVECair touch + SAVE Connect app
Integrated touchscreen · WiFi remote · Modbus integration
A single VTR 300/B unit serves homes up to 240 m². Filtered fresh air is supplied to habitable rooms (bedrooms, living rooms, study); stale air is extracted from wet rooms (kitchens, bathrooms, utility). Two EC RadiCal fans run continuously to maintain balanced pressure across the whole home.
A slowly-rotating aluminium wheel sits between the supply and extract air streams. Each side absorbs heat from the warm air it passes, then releases it into the cooler air on the next rotation. This design also transfers some humidity back into the supply — preventing winter dryness without an enthalpy core.
Factory-fitted F7 (ISO ePM1 60%) on the supply side and M5 (ISO ePM10 60%) on the extract side. F7 catches pollen, fine dust, smog particles and combustion residue. The control panel's filter timer flags replacement, typically every 6–12 months depending on outdoor air quality.
A built-in humidity sensor in the extract air enables demand control as standard — the unit ramps fan speed when shower steam or kitchen activity drives RH up. Optional CO₂ sensor adds occupancy-driven control. Manual override always available via the SAVECair touchscreen.
A dedicated cooker-hood inlet on the top of the unit routes kitchen extract air around the heat exchanger rather than through it. Result: no grease accumulation on the rotor, no service disruption, no impact on heat recovery efficiency. A subtle but consequential design choice.
An integrated electric reheater downstream of the rotor maintains a comfortable supply air temperature even at outdoor temperatures of −10°C. The reheater is thermostatically controlled — only draws power when needed. Required for Passivhaus comfort criterion (supply air ≥16.5°C at −10°C outdoor).
The VTR 300/B has a SAVECair colour touchscreen integrated into the front door, plus optional SAVE CONNECT WiFi/cloud, Modbus RS-485, and an external CD4 wired control panel. Designed for direct hands-on control or full app/BMS integration.
SAVECair touchscreen
Full-colour touchscreen integrated in the unit's front door. Fan speed selection, week schedule, alarm history, filter status, sensor inputs, commissioning wizard. The default operating interface — no separate panel required.
SAVE CONNECT (WiFi)
WiFi accessory module for remote access via the SAVE Connect mobile app (iOS and Android) or the homesolutions.systemair.com web portal. Local or remote control, no LAN cabling required, links to Amazon Alexa and Google Home.
Modbus RS-485
Standard on every unit. Direct integration with home automation and BMS systems via Modbus protocol — useful for commercial installs (offices, classrooms) where ventilation needs to integrate with heating and lighting control.
CD4 external control panel
Optional wired wall-mounted control panel for installations where the integrated SAVECair touchscreen on the unit isn't at a convenient location. Same control set, repeated at a wall position elsewhere in the home.
Built-in humidity sensor
Standard — fitted in the extract air chamber from factory. Demand control is enabled out of the box: the unit ramps fan speed when extract RH rises (shower, cooking, drying laundry). No optional sensor needed for this.
Optional CO₂ sensor
Add-on CO₂ sensor for occupancy-driven control. Useful for home offices, classrooms, and bedrooms where humidity-only control isn't enough. Wires directly into the connection board on the side of the unit.
Week schedule
Built into the SAVECair controller — set up to two airflow time periods per day across each day of the week. Useful for homes with predictable occupancy patterns (away during working hours, busier in evenings).
Boost / refresh mode
Timed boost at high speed for clearing odours after cooking, fast air change after gatherings, or post-shower humidity. Returns to scheduled airflow automatically. Triggered via touchscreen, app, or external switch.
Through-wall installation with a larger Ø270 mm core drill. Often installed as a pair on opposing walls in conference rooms or classrooms for whole-room balanced ventilation.
Centralised whole-house MVHR. The VTR 300/B plant unit sits in a service location (utility room, plant cupboard, loft) with four duct runs to fresh-air intake, exhaust outlet, supply manifold, and extract manifold. Wall-mounted vertically with top-connected ducts.
VTR 300/B plant unit
Double-skinned panels, white painted sheet steel construction. Wall-mounted vertically on supplied bracket. Left-hand or right-hand duct configuration (separate SKUs — confirm at order). SAVECair touchscreen integrated in the front door.
Rotary heat exchanger
Variable-speed rotating exchanger with moisture transfer. Approximately 14 kg, removable from the front for cleaning every 3 years (or sooner if the airflow performance drops). Drive belt is the only consumable hardware in the rotor mechanism.
EC RadiCal fans
Two RadiCal impeller fans with EC (electronically commutated) motors. Modern brushless DC technology — quiet operation, low specific fan power, 50% less energy than equivalent AC motors. Lifetime-lubricated bearings, maintenance-free.
Four duct spigots (top-connected)
All four ducts (intake, exhaust, supply, extract) connect on the top of the unit. Compatible with standard EU residential MVHR duct sizes — confirm exact spigot diameter at design stage. Cooker hood inlet is also on top.
F7 + M5 filter set
Factory-fitted F7 (ISO ePM1 60%) supply filter and M5 (ISO ePM10 60%) extract filter. Tool-free replacement via the front hatch. G3 alternative available for smaller-particle environments where F7 isn't required.
Integrated 1670 W reheater
Electric reheater downstream of the rotor — maintains supply air ≥16.5°C even at outdoor temperatures of −10°C (Passivhaus comfort criterion). Thermostatically controlled, only draws power when needed.
Cooker hood bypass
Dedicated kitchen extract inlet on top of the unit. Cooker-hood air bypasses the heat exchanger entirely — no grease accumulation on the rotor, no service disruption from cooking residue.
SAVE CONNECT cloud module
Optional WiFi accessory for remote control via the SAVE Connect mobile app or web portal. Plugs into the connection board on the side of the unit. Required for app control, not needed for local SAVECair touchscreen operation.
The VTR 300/B is engineered for long-term low-touch operation. Filters change in under five minutes; the rotor is removable for periodic cleaning; the ductwork itself has no moving parts. Most homeowners self-maintain; we offer optional servicing for those who don't want to.
2-year manufacturer warranty
Systemair provides a 2-year manufacturer warranty on the unit as standard. Built to Eurovent certification and ErP compliance with global service network. Mature platform — Systemair has been making rotary MVHR since 1974.
Filter change every 6–12 months
F7 supply and M5 extract filters, accessed by opening the front hatch. Tool-free replacement. The SAVECair touchscreen flags when change is due (default 12 months, adjustable 3–15 months). Filter sets typically £25–40 from UK distributors.
Removable rotary exchanger
The heat exchanger lifts out from the front for cleaning every 3 years (or sooner if airflow performance drops). Approximately 14 kg — two-person lift recommended. Wash in hot soapy water (no ammonia detergents).
Drive belt — replaceable
A rubber drive belt rotates the heat exchanger via the rotor motor. The SAVECair controller flags an alarm if the belt slips or breaks. Replacement is straightforward — Systemair supplies the belt as a service spare. Plan for one belt change in a 10-year service life.
Ductwork — no scheduled maintenance
Once correctly installed and balanced, modern smooth-bore plastic ductwork runs maintenance-free. Periodic visual inspection of intake/exhaust grilles for leaf or debris accumulation is the only routine task.
Optional CleverBloom service plan
For homeowners who don't want to self-maintain, CleverBloom offers an annual visit covering filter change, rotor inspection, flow rate verification with anemometer, and any sensor recalibration. Specify at handover.
Heat pump unit only. Radiators, UFH, and emitters are on the heating page.
£3,113
Equipment only · no installation
What's included
Optional add-ons
£5,613
Fully installed (excl. ductwork & silencers) · equipment + design, install & commissioning
What's included
Optional add-ons
£3,113
Equipment only · no installation
What's included
Optional add-ons
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur.
Block quote
Ordered list
Unordered list
Bold text
Emphasis
Superscript
Subscript

_11zon%20(1).webp)
Call us at 07526 985258
or leave your contact information below,
and we'll get back to you soon.
Join our certified installer network — leads, products, and technical support provided.
We provide smart technology for homes and commercial spaces, ensuring transparent processes and optimal resource management.
Working hours: Mon - Sun. 8am - 8pm
Proudly serving the entire UK!
© 2026 Clever Bloom — All rights reserved
Company registered in England and Wales / Company number: 14242566.